Spec

  • Filtration area, m

    2

    : 0.65
  • Filter bore diameter, μm: 0.2
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, cm (inch): 33.5 (13.2)
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophobicity PTFE
  • Housing: Polypropylene
  • Filter brand name: Aervent
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Substitute: SN2M027A6
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Vent/drain: 1/4in. hose port with double O-ring seal
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XL10 Aervent 0.2μm 1-1/2in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    24mL/min at 96.5kPa (14psig) 70//30% IPA/water
  • Hydro-Core test:


    0.75?mL/min @ 260?kPa (38?psig)
  • Bubble point, 23 °C:


    110kPa (16psig) 70/30% IPA/water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 414 (60) at 25℃, intermittent
  • Wettability: Hydrophobicity
  • Sterilization: Autoclave sterilization at 135℃ for 30 minutes for 30 times; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Nitrogen diffusion flow rate, 23 °C:


    10mL/min at 170kPa (25psig) water-wet
  • Total extract: The extractables level was equal to or less than 45


    mg after 24


    hours in a 70/30%


    IPA/water mixture at controlled room temperature.

Related product recommendations

You may also be interested in the following products

62-8482-52 EmbryoMax(R) Filtered Light Mineral Oil; 100 mL ES-005-C
Analyzer, Testing Equipment

62-8482-52 EmbryoMax(R) Filtered Light Mineral Oil; 100 mL ES-005-C

model: 62-8482-52 brand: Sigma Aldrich Japan(Millipore)
62-8395-12 EZ-Nuclear RIP (Cross-Linked) Kit 17-10521
Analyzer, Testing Equipment

62-8395-12 EZ-Nuclear RIP (Cross-Linked) Kit 17-10521

model: 62-8395-12 brand: Sigma Aldrich Japan(Millipore)
62-8504-73 Anti-THAP11, clone 3F3 MABD172
Analyzer, Testing Equipment

62-8504-73 Anti-THAP11, clone 3F3 MABD172

model: 62-8504-73 brand: Sigma Aldrich Japan(Millipore)
62-8488-28 CellASIC ONIX switching plate for mammalian cells (4 chamber) M04S-03-5PK
Analyzer, Testing Equipment