65-1915-44 Diffusion type and mounting type oxygen measuring device OPA-6000E
Product Description
Product Model: 65-1915-44Product Brand: KITAGAWA, KOMYO […]
Contact Us
Product Details
Product Model: 65-1915-44
Product Brand: KITAGAWA, KOMYO RIKAGAKU KOGYO K. K.
Features
- Explosion-Proof Approved Product (Essential Safety Explosion-Proof Structure).
- With vibration alarm function (vibration function).
- JIS T 8201 Oxygen meter compliant product for measuring oxygen deficiency.
- They respond quickly to standing up and standing down.
- Telemetry is possible (up to 30 m) with optional extension cord and connection adapter.
- It can be measured in inert gases such as nitrogen and carbon dioxide.
- It is not affected by acid gases such as hydrogen sulfide and sulfur dioxide.
- It is a downward sensor that is not affected by water droplets and dust.
- By wearing it, you can measure the concentration change in the workplace in real time.
Spec
- Target gas: atmospheric oxygen (O2)
- Measurement Method: Diffusion
- Measurement principle: Galvanic battery type (sensor type: OC-6B)
- Measurement range: 0.0~50.0vol% (minimum display: 0.1vol%)
- instruction accuracy
- 25.0vol% or less: ±0.5vol%
- 25.1vol% or more: ±3.0vol% * 1
- Alarm setting value (shipped): AL1/18. 0vol%
- Response time: 90% Response within 15 seconds (at 20°C)
- Alarm system: LED lamp, LCD display, buzzer, vibration
- Explosion-Proof Structure: Ex ia II CT4 Ga TC No. 22742
- Operating temperature and humidity range: -10~40°C, 30~85%RH (non-condensing)
- Power supply: 3 AAA alkaline batteries (LR03)
- Continuous service time: Approx. 1000 hours * 2
- Body Dimensions: W105 x H56 x D29mm (excluding sensor section)
- Mass: approx. 150 g (including battery)
- Standard Accessories: Body Case (w/Clip)
- Product Structure: Main Unit, AA Alkaline Batteries x 3, Case for Main Unit (w/Clip), Owner's Manual, Warranty
- Optional (sold separately): OPA sensor extension cord (5 m, 10 m, 20 m, 30 m), requires a separate adapter
- *1 When using a sensor that is within the expiration date and under the same conditions as when calibrating.
- *2 In case of no alarm using new batteries. Continuous *** time may vary dep***ing on battery manufacturer and ambient conditions.
Related product recommendations
You may also be interested in the following products
61-9414-34 Gas Detector Tube Benzene with Calibration Certificate (With Certificate Of Test) 121S
model: 61-9414-34
brand: GASTEC Corporation
65-3514-39 Sealed Coupled Meter Type A Vibration-Resistant Pressure Range (MPA): -0.1~0.1 325-A480X0.1-0.1MPA-MV
model: 65-3514-39
brand: Asahi Gauge Manufacturing
67-4842-25 [Discontinued]Handymanometer (0 to -100 kPa, Negative Pressure) PG-100-102VP 0232-01-0000050
model: 67-4842-25
brand: Copal Electronics