61-0248-66 Opticap XL5 Polygard-Cr 0.5μm 9/16In. HB/HB 1/Pk 1ST KRA5A05HH1
Analyzer, Testing Equipment

61-0248-66 Opticap XL5 Polygard-Cr 0.5μm 9/16In. HB/HB 1/Pk 1ST KRA5A05HH1

model: 61-0248-66
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0248-66Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0248-66
Product Brand: Merck Millipore Corporation

Spec

  • Diameter, cm (inch): 10.7 (4.2)
  • Length, Inch (cm): 5 (12.5)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Polypropylene
  • Housing: Polypropylene
  • Format: Single Layer
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 14mm (9/16in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XL5 Polygard-CR 0.5μm 9/16in. HB/HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Nominal bore diameter, μm: 0.5
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): 483 (70) @ 25


    °C
  • Sterilization: Autoclave sterilization 3 times for 30 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 30


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Conform to USP Oxidizable Substances Test after flashing with next water ?2.5L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

3-2440-01 PTFE Bubbler (Round Shape) Φ50 x 15 50
Analyzer, Testing Equipment
62-8518-66 Anti-Flavoprotein subunit of complex II (SDHA) MABN630
Analyzer, Testing Equipment

62-8518-66 Anti-Flavoprotein subunit of complex II (SDHA) MABN630

model: 62-8518-66 brand: Sigma Aldrich Japan(Millipore)
62-8380-92 [Discontinued]CK1δ Inhibitor, SR-1277 5.38340.0001
Analyzer, Testing Equipment
2-8205-01 Microbiological Test Paper, General Bacteria 100 Pieces 080510-302
Analyzer, Testing Equipment

2-8205-01 Microbiological Test Paper, General Bacteria 100 Pieces 080510-302

model: 2-8205-01 brand: SIBATA SCIENTIFIC TECHNOLOGY LTD.