![63-8457-15 [Discontinued]Biospectrometer Fluorescence Micromeasurement Set 6137 000.902](https://www.jgauge.com/wp-content/uploads/2025/09/32b187e096c6c338b570ce51ab5ccf53.webp)
Analyzer, Testing Equipment
63-8457-15 [Discontinued]Biospectrometer Fluorescence Micromeasurement Set 6137 000.902
Product Description
Product Model: 63-8457-15Product Brand: Eppendorf AG Fe […]
Contact Us
Product Details
Product Model: 63-8457-15
Product Brand: Eppendorf AG
Features
- Biospectrometer Fluorescent and micromeasurement cuvette μCuvette G1.0 set item
- Biospectrometer Fluorescent
- Biospectrometer series that can scan with continuously variable wavelength
- Fluorescent model that can measure fluorescence intensity
- All functions of Biospectrometer Basic are available. Since both absorbance measurement and fluorescence intensity can be measured, sensitive determination of samples beyond the detection range of absorbance measurement with a fluorescent reagent is possible on a single device. For example, in the case of DNA, the measured concentration range is expanded by 1000 times.
- The wavelength can be freely selected in the entire spectral range (Biospectrometer series: 1 nm increments)
- The program is pre-installed, so you can *** it immediately.
- Compact A3 size, no PC connection required
- Data can be exported to a USB memory or PC
- Results can be printed directly (optional thermal printer DPU-S445 required separately)
- Extremely long-life xenon flash lamp
- Help box for displaying instructions for each step in 6 languages (including Japanese)
- Both micromeasurement cuvettes and standard cuvettes can be ***d
- Micromeasurement cuvette μCuvette G1.0
- The μCuvette G1.0 has an optical path length of only 1 mm, 1/10 that of a standard cuvette. This allows the measurement of high concentrations of nucleic acids and proteins, with a minimum sample size of 1.5 μL.
- Measurements with a sample volume of 1.5 ~ 10 μL
- For nucleic acid and protein concentration measurement
- High concentration samples can be measured without sample dilution
- Dedicated for Biophotometer Series and Biospectrometer Series
Spec
- Set Contents: Bio-Spectrometer Fluorescent Body x 1, μCuvette G 1.0 x 1 piece
- Bio-Spectrometer Fluorescent Body x 1
- Light source (light absorption): Xenon flash lamp
- Light Source (Fluorescent): LED
- Ray Height: 8.5 mm
- Optical system (absorption): single beam absorption spectrum measurement using a reference beam.
- Optical system (fluorescence): confocal fluorometry using a reference beam
- Detector (Absorption): CMOS photodiode array
- detector (fluorescent): photodiode
- Wavelength Range (Absorption): Scanning (nm): 200 to with 830, 1 nm increments
- Excitation wavelength: 470 nm, bandwidth: 25 nm
- Fluorescence wavelength: 520 nm, bandwidth: 15 nm, 560 nm, bandwidth: 40 nm
- Bandwidth (absorption): < 4 nm
- Absorbance measurement range: 0A to 3.0 A (260 nm)
- Fluorescence intensity measurement range: 0.5 nM to 2000 nM Fluorescein (fluorescence wavelength: 520 nm)
- dsDNA concentration range: 1.0 pg/μL to 1500 ng/μL
- Interface: USB Master: For USB Memory, Thermal Printer/USB Slave: For PC Connection/RS -232 C: For Thermal Printer
- Size (W x D x H): 295 x 400 x 150 mm
- Weight: 5.4 kg
- continuous wavelength measurement
- fluorometry
- Cuvette G 1.0 for Trace Measurement
- dsDNA measurement range: 25 to 1500 ng/μL * 1
- * 1 Recomm***ed concentration range: 50 to 500 ng/μL
- Application example: Nucleic acid/protein concentration measurement
- UV Transmission: > 180 nm
- Wavelength Range: 180 to 2000 nm
- Size (W x D x H): 12.5 x 12.5 x 48 mm
- capacity: 1.5 to 10 μL * 2
- * 2 We recomm*** at least 3 μL for protein concentration measurement.
- Optical path length: 1 mm
- Base absorbance (260 nm): < 0.05 A
- Ray Height: 8.5 mm
- Cuvette for trace measurement
Related product recommendations
You may also be interested in the following products
62-8484-46 Milli-Mark(TM) Anti-CD42b-PE, clone AN51; 100 tests FCMAB196P
model: 62-8484-46
brand: Sigma Aldrich Japan(Millipore)
62-8387-42 Anti-phospho-PLK1 (Ser137); 100 μg 07-1348
model: 62-8387-42
brand: Sigma Aldrich Japan(Millipore)
62-8509-84 [Discontinued]Anti-IL-10 (human), PE, clone JES3-19F1 MABF328
model: 62-8509-84
brand: Sigma Aldrich Japan(Millipore)
62-8488-13 Leukemia Inhibitory Factor, recombinant mo***; 5 μg LIF2005
model: 62-8488-13
brand: Sigma Aldrich Japan(Millipore)