61-0253-38 [Discontinued]Opticap XLT20 Viresolve NFR 1.5In. TC/TC 1/Pk 1ST KZRVA2TTT1
Analyzer, Testing Equipment

61-0253-38 [Discontinued]Opticap XLT20 Viresolve NFR 1.5In. TC/TC 1/Pk 1ST KZRVA2TTT1

model: 61-0253-38
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0253-38Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0253-38
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.854
  • Length from inlet to outlet, cm (inch): 15.2 (6.0)
  • Hold-up volume, mL: 325
  • Processing capacity, L: 1200?2400
  • Length, cm (inch): 63.5 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Polyethersulfone
  • Application: Retrovirus removal
  • Brand name: Viresolve
  • Main application: Protein Purification
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Vent/drain: 1/4in. hose port double O-ring seal
  • Connection, Inlet/outlet: 38 mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XLT 20 Viresolve NFR 1-1/2in. TC/TC
  • Product name: Opticap XLT 20 capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C: ?32mL/minute @ 340kPa (50psig), moisted in water
  • Maximum input pressure, kPa (psi): 550 (80) @ 23 °C
  • Maximum differential pressure, kPa (psid): Forward: 550(80), reverse direction: 340(50)
  • Sterilization: After wetting, Liquid cycle, with slow exhaust, Autoclave sterilization at 125℃ for 60 minutes, available up to 3 times
  • Total extract: The extractables level was equal to or less than 70


    mg after a 10


    minute 1.5


    LPM/ft2 flush and 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Effluent after flashing with 8L of water conforms to USP Oxidizable Substances Test
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0329-76 [Discontinued]4-Bromotoluene for Synthesis 801637 250G 8.01637.0250
Analyzer, Testing Equipment
62-8510-93 Anti-CD62L (L-Selectin) (mo***), APC, clone MEL-14 MABF450
Analyzer, Testing Equipment

62-8510-93 Anti-CD62L (L-Selectin) (mo***), APC, clone MEL-14 MABF450

model: 62-8510-93 brand: Sigma Aldrich Japan(Millipore)
62-8392-49 Anti-β-Tubulin, clone AA2, Alexa Fluor(R) 488 conjugate; 100 μg 16-230
Analyzer, Testing Equipment
62-8472-28 Anti-Endophilin-A1; 100 μL ABT22
Analyzer, Testing Equipment

62-8472-28 Anti-Endophilin-A1; 100 μL ABT22

model: 62-8472-28 brand: Sigma Aldrich Japan(Millipore)