Spec

  • Filtration area, m

    2

    : 0.43
  • Length from inlet to outlet, cm (inch): 15.2 (6.0)
  • Hold-up volume, mL: 175
  • Processing capacity, L: 600?1200
  • Length, cm (inch): 38 (15)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Polyethersulfone
  • Application: Retrovirus removal
  • Brand name: Viresolve
  • Main application: Protein Purification
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Vent/drain: 1/4in. hose port double O-ring seal
  • Connection, Inlet/outlet: 38 mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XLT 10 Viresolve NFR 1-1/2in. TC/TC
  • Product name: Opticap XLT 10 capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C: ?16mL/minute @ 340kPa (50psig), moisted in water
  • Maximum input pressure, kPa (psi): 550 (80) @ 23 °C
  • Maximum differential pressure, kPa (psid): Forward: 550(80), reverse direction: 340(50)
  • Sterilization: After wetting, Liquid cycle, with slow exhaust, Autoclave sterilization at 125℃ for 60 minutes, available up to 3 times
  • Total extract: The extractables level was equal to or less than 35


    mg after a 10


    minute 1.5


    LPM/ft2 flush and 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Effluent after flashing with 4L of water conforms to USP Oxidizable Substances Test
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

2-9157-01 [Discontinued]Microorganisms Sensor BM-300C
Analyzer, Testing Equipment
61-0295-37 Mercury(II) Bromide For Analysis GR Emsure(TM)  ACS, Reag. Ph Eur 104421 250G 1.04421.0250
Analyzer, Testing Equipment
61-0338-49 [Discontinued]4-Nitrotoluene for Synthesis 806807 100G 8.06807.0100
Analyzer, Testing Equipment