61-0251-60 [Discontinued]Opticap Gamma Compatible Sterilizing Grade XLT20 Durapore 0.1μm 5/8In HB/HB 1/Pk 1ST KVVLG2THH1
Analyzer, Testing Equipment

61-0251-60 [Discontinued]Opticap Gamma Compatible Sterilizing Grade XLT20 Durapore 0.1μm 5/8In HB/HB 1/Pk 1ST KVVLG2THH1

model: 61-0251-60
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0251-60Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0251-60
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 1.38
  • Length from inlet to outlet, cm (inch): 19.8 (7.8)
  • Filter bore diameter, μm: 0.1
  • Length, cm (inch): 62.5 (24.6)
  • Length, Inch (cm): 20 (50)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Gamma compatible polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Form: Capsule
  • Connection, Inlet/outlet: 16mm (5/8in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT20 Durapore 0.1μm gamma compatible 5/8in. HB/HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    42.2mL/min at 390kPa (56psig) wetted with water
  • Bubble point, 23 °C:


    483kPa (70psig) water-wet and air
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 50


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 2L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8508-18 Anti-Nup98 Antibody, clone 2H10 MABE1040
Analyzer, Testing Equipment

62-8508-18 Anti-Nup98 Antibody, clone 2H10 MABE1040

model: 62-8508-18 brand: Sigma Aldrich Japan(Millipore)
62-8551-02 TSA Contact + Neutralizer A – ICR+ 1.46697.0020
Analyzer, Testing Equipment

62-8551-02 TSA Contact + Neutralizer A – ICR+ 1.46697.0020

model: 62-8551-02 brand: Merck Millipore Corporation
61-0393-05 [Discontinued]Boc-Arg(Di-Z)-OH 853036 25G 8530360025
Analyzer, Testing Equipment

61-0393-05 [Discontinued]Boc-Arg(Di-Z)-OH 853036 25G 8530360025

model: 61-0393-05 brand: Merck Millipore Corporation
64-1072-40 ILC Column  40φDedicated  Parts Glass Column K-8-40-300
Analyzer, Testing Equipment