Product Details

Product Model: 61-0251-60
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 1.38
  • Length from inlet to outlet, cm (inch): 19.8 (7.8)
  • Filter bore diameter, μm: 0.1
  • Length, cm (inch): 62.5 (24.6)
  • Length, Inch (cm): 20 (50)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Gamma compatible polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Form: Capsule
  • Connection, Inlet/outlet: 16mm (5/8in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT20 Durapore 0.1μm gamma compatible 5/8in. HB/HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    42.2mL/min at 390kPa (56psig) wetted with water
  • Bubble point, 23 °C:


    483kPa (70psig) water-wet and air
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 50


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 2L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0257-81 Manifold Tee, 1.5 In. 316 Stainless Steel; 1 Each 1ST MP0DSSTEE
Analyzer, Testing Equipment
61-0387-18 [Discontinued]Fmoc-Tyr(2-Cltrt)-OH 852080 5G 8520800005
Analyzer, Testing Equipment
61-0307-89 2-Propanol for Analysis Emsure(TM) ACS, ISO, Reag. pH Eur 109634 2.5L 1.09634.2500
Analyzer, Testing Equipment
61-0210-94 Millex-Hv 0.45μm PVDF 13mm Non-Sterile; 1000/Pk 1000PK SLHVX13NK
Analyzer, Testing Equipment