61-0251-38 [Discontinued]Opticap XLT30 Durapore 0.1μm 1In. HB/HB; 1/Pk 1ST KVVLA3TBB1
Analyzer, Testing Equipment

61-0251-38 [Discontinued]Opticap XLT30 Durapore 0.1μm 1In. HB/HB; 1/Pk 1ST KVVLA3TBB1

model: 61-0251-38
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0251-38Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0251-38
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 2.07
  • Filter bore diameter, μm: 0.1
  • Length, cm (inch): 30
  • Length, Inch (cm): 30 (75)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 25mm (1in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT30 Durapore 0.1μm 1in. HB/HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    60mL/min at 390kPa (56psig) water-wet
  • Bubble point, 23 °C:


    483kPa (70psig) water-wet and air
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 3L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8369-96 [Tyr(PO3H2)4]-Angiotensin II, Human 05-23-0111-5MG
Analyzer, Testing Equipment
61-0229-79 Milligard Cart Filt 30In. Code 7 0.5/0.2μm 3/Pk 3 x 1ST CWSS73S03
Analyzer, Testing Equipment
62-8347-34 Opticap Sterile XLT10 Express SHF 0.2μm 1inHB/HB 1/Pk KGEPS1TBB1
Analyzer, Testing Equipment
61-0247-53 [Discontinued]Opticap XL10 Polygard-CN 2.5μm 3/4In. TC/TC 1/Pk 1ST KN25A10FF1
Analyzer, Testing Equipment