61-0251-19 [Discontinued]Opticap Sterilizing Grade XL10 Multimedia 0.5/0.2/0.22μm 1.5InTC/TC 1/Pk 1ST KVSSA10TT1
Analyzer, Testing Equipment

61-0251-19 [Discontinued]Opticap Sterilizing Grade XL10 Multimedia 0.5/0.2/0.22μm 1.5InTC/TC 1/Pk 1ST KVSSA10TT1

model: 61-0251-19
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0251-19Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0251-19
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.56
  • Filter bore diameter, μm: 0.5 / 0.2 / 0.22
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, cm (inch): 33.5 (13.2)
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Cellulose mixed ester
  • Vent cap material: Polypropylene
  • Material: Cellulose mixed ester; hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Substitute: SN2M013A99
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XL10 multimedia 0.5/0.2/0.22μm 1-1/2in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    10.8mL/min @ 280kPa (40 psig) in water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Highest operating temperature, ℃: 80 °C
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 5L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8391-76 p53-GST (recombinant protein); 50 μg 14-865
Analyzer, Testing Equipment

62-8391-76 p53-GST (recombinant protein); 50 μg 14-865

model: 62-8391-76 brand: Sigma Aldrich Japan(Millipore)
62-8401-20 pET-30a(+) DNA 69909-3
Analyzer, Testing Equipment

62-8401-20 pET-30a(+) DNA 69909-3

model: 62-8401-20 brand: NVG(Merck)
62-8508-89 [Discontinued]Anti-Interleukin-22 (IL-22), clone 2D5; 100 μg MABF49
Analyzer, Testing Equipment
62-8382-98 [Discontinued]Anti-RelB; 100 μg 06-1105
Analyzer, Testing Equipment

62-8382-98 [Discontinued]Anti-RelB; 100 μg 06-1105

model: 62-8382-98 brand: Sigma Aldrich Japan(Millipore)