61-0243-77 [Discontinued]Opticap XLT30 Polysep II 2.0/1.2μm 1In. HB/HB 1/Pk 1ST KGW9A3TBB1
Analyzer, Testing Equipment

61-0243-77 [Discontinued]Opticap XLT30 Polysep II 2.0/1.2μm 1In. HB/HB 1/Pk 1ST KGW9A3TBB1

model: 61-0243-77
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0243-77Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0243-77
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 1.38
  • Length, cm (inch): 30
  • Length, Inch (cm): 30 (75)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Borosilicate glass Fiber
  • Vent cap material: Polypropylene
  • Material: Cellulose mixed ester
  • Housing: Polypropylene
  • Format: Double Layer
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 25mm (1in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT30 Polysep II 2.0/1.2μm 1in. HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Nominal bore diameter, μm: 2,0 / 1,2
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): 345 (50) @ 25


    °C
  • Sterilization: Autoclave sterilization 3 times for 30 minutes at 121℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 435


    mg per capsule after a 15


    L flush and 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 15L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0366-07 [Discontinued]1-Phenyloctane for Synthesis 821006 25mL 8.21006.0025
Analyzer, Testing Equipment
62-8493-89 Anti-Zyxin, clone 14E11.1; 100 μg MAB2610
Analyzer, Testing Equipment

62-8493-89 Anti-Zyxin, clone 14E11.1; 100 μg MAB2610

model: 62-8493-89 brand: Sigma Aldrich Japan(Millipore)
62-8511-78 Anti-CD4 (human), PE, clone OKT4 MABF573
Analyzer, Testing Equipment

62-8511-78 Anti-CD4 (human), PE, clone OKT4 MABF573

model: 62-8511-78 brand: Sigma Aldrich Japan(Millipore)
62-8532-95 STEMCCA Constitutive Polycistronic (OKSM) Lentivirus Reprogramming Kit; 1 kit SCR530
Analyzer, Testing Equipment