![61-0243-73 [Discontinued]Opticap XLT20 Polysep II 2.0/1.2μm 1In. HB/HB 1/Pk 1ST KGW9A2TBB1](https://www.jgauge.com/wp-content/uploads/2025/08/21ac41fed13efc4f5ddde48d9e09bd2f.webp)
Analyzer, Testing Equipment
61-0243-73 [Discontinued]Opticap XLT20 Polysep II 2.0/1.2μm 1In. HB/HB 1/Pk 1ST KGW9A2TBB1
Product Description
Product Model: 61-0243-73Product Brand: Merck Millipore […]
Contact Us
Product Details
Product Model: 61-0243-73
Product Brand: Merck Millipore Corporation
Spec
-
Filtration area, m
2
: 0.92 - Length, cm (inch): 20
- Length, Inch (cm): 20 (50)
- Support material: Polypropylene
- Seal material: Silicone
- Device material: Polypropylene
- Pre-filter material: Borosilicate glass Fiber
- Vent cap material: Polypropylene
- Material: Cellulose mixed ester
- Housing: Polypropylene
- Format: Double Layer
- Brand name: Opticap
- Main application: Laboratory Filtration
- Package: Double easy open bag
- Form: Capsule
- Connection, Inlet/outlet: 25mm (1in.) hose port
- Quantity/box: 1
- Overview: Opticap XLT20 Polysep II 2.0/1.2μm 1in. HB
- Product name: Opticap XLT capsule filter
- Maximum Inlet Pressure (psig): 80
- Maximum Inlet Temperature, °C: 25
- T-line/Gauge Port: T-line
- Nominal bore diameter, μm: 2,0 / 1,2
-
Maximum input pressure, kPa (psi): 552 (80) @ 25
°C; 276 (40) @ 60
°C; 103 (15) @ 80
°C -
Maximum differential pressure, kPa (psid): 345 (50) @ 25
°C - Sterilization: Autoclave sterilization 3 times for 30 minutes at 121℃; no in-line steam sterilization
- Sterility: No sterilization
-
Total extract: The extractables level was equal to or less than 290
mg per capsule after a 10
L flush and 24
hours in water at controlled room temperature. - Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 10L
- ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.
Related product recommendations
You may also be interested in the following products
62-8383-21 Anti-phospho-TAB1 (Thr431); 100 μg 06-1334
model: 62-8383-21
brand: Sigma Aldrich Japan(Millipore)
61-0313-04 M Color Test(TM) Cyanide Test Measurement Principle: Colorimetric Analysis (Using Color Disk) Mcolortest(TM) 114798 200Tests 1.14798.0001
model: 61-0313-04
brand: Merck Millipore Corporation
4-6109-01 Violamo 2 Layer Structure Syringe Filter (Hydrophilic PTFE) 0.22 μm φ25 mm 1 Box (100 Pieces) PTFEG-025S022I
model: 4-6109-01
brand: VIOLAMO
62-8522-27 Anti-PTP1B, clone FG6-1G MABS197
model: 62-8522-27
brand: Sigma Aldrich Japan(Millipore)