61-0243-12 [Discontinued]Opticap XL4 Polysep II 1.0/1.2μm 3/4In.Tc-9/16In.Hb 3/Pk 3 x 1ST KGW2A04FH3
Analyzer, Testing Equipment

61-0243-12 [Discontinued]Opticap XL4 Polysep II 1.0/1.2μm 3/4In.Tc-9/16In.Hb 3/Pk 3 x 1ST KGW2A04FH3

model: 61-0243-12
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0243-12Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0243-12
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.11
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, Inch (cm): 4 (10)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Borosilicate glass Fiber
  • Vent cap material: Polypropylene
  • Material: Cellulose mixed ester
  • Housing: Polypropylene
  • Format: Double Layer
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange/14mm (9/16in.) hose port
  • Quantity/box: 3
  • Overview: Opticap XL4 Polysep II 1.0/1.2μm 3/4in.TC-9/16in. HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Nominal bore diameter, μm: 1.0 / 1.2
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): 345 (50) @ 25


    °C
  • Sterilization: Autoclave sterilization 3 times for 30 minutes at 121℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 85


    mg per capsule after a 1200


    mL flush and 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 2L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

64-3319-43 Membrane Roll 300 mm x 3M CA 0.22 μm 1224211
Analyzer, Testing Equipment
61-0365-58 [Discontinued]Oxetane for Synthesis 820937 5mL 8.20937.0005
Analyzer, Testing Equipment
2-858-01 [Discontinued]Syringe Filter (ASFIL) 013022S-SFNY SFNY013022S
Analyzer, Testing Equipment
62-8346-37 Opticap Autoclavable XLT30 Express SHF 0.2μm 1.5in TC/TC 1/Pk KGEPA3TTT1
Analyzer, Testing Equipment