Analyzer, Testing Equipment
3-5073-01 Energy Dispersive Fluorescence X-Ray Analysis Device EDX-7000
model:
3-5073-01
category:
Analyzer, Testing Equipment
Product Description
Product Model: 3-5073-01 Features Specimens of up to 30 […]
Contact Us
Product Details
Product Model: 3-5073-01
Features
- Specimens of up to 300 x 275 x about 100 mm can be set.
- You can easily set the analysis position while checking the camera image.
- High-performance SDD detector, which does not require the supply of liquid nitrogen, enables high sensitivity and high speed analysis.
Spec
- Model number: EDX-7000
- Size (mm): 460 x 590 x 360
- Weight (kg): Approx 45
- Set content: Body, PC for control
- Measurement principle: Fluorescence X-ray analysis method
- Measuring method: Energy dispersive type
- Measurement target: Solid, Liquid, Powder
- Measurement range: 11Na - 92U
- Sample chamber size: Maximum 300 x 275 x approx. 100mm
- Maximum sample weight: 5kg *1
- Cooling method: Air cooling (with fan)
- Irradiation area: φ1・3・5・10mm
- Primary filter: 5 types + OPEN
- Type: Silicone drift detector (SDD)
- Measurement atmosphere: Atmospheric air
- Sample observation: CMOS camera
- Power supply: Single-phase AC100V 50/60Hz
- Power cord length: 2.5m
- Measurement principle: Fluorescence X-ray analysis method
- Measuring method: Energy dispersive type
- Measurement target: Solid, liquid, powder
- Measurement range: 11Na - 92U
- Sample chamber size: Maximum 300 x 275 x approx. 100mm
- Maximum sample weight: 5kg *when using turret, Sample/200g, Total weight/2.4kg
- Cooling method: Air cooling (with fan)
- Irradiation area: φ1・3・5・10mm
- Primary filter: 5 types + OPEN
- Type: Silicone drift detector (SDD)
- Measurement atmosphere: Atmospheric air
- Sample observation: CMOS camera
- Power supply: Single-phase AC100V 50/60Hz
- Power cord length: 2.5m
- *We have 3 type screening analysis kit (for RoHS, for RoHS + chlorine, for RoHS + chlorine + antimony) ideal for screening analysis. Please contact with us separately. *12 samples turret, vacuum exhaust, helium replacement are optional.
Related product recommendations
You may also be interested in the following products
62-8454-80 Anti-Glycine Receptor alpha3 subunit ; 100 μg AB15014
model: 62-8454-80
brand: Sigma Aldrich Japan(Millipore)
61-0247-66 Opticap XL10 Lifegard 1.0μm 9/16In. HB/HB 1/Pk 1ST KP15A10HH1
model: 61-0247-66
brand: Merck Millipore Corporation
61-0321-74 Germanium ICP Standard Solution Traceable For SRM Of NIST[(NH4) 2GeF6 in H2O], 1000mg/L Ge Certipur(R) 170320 100mL 1.70320.0100
model: 61-0321-74
brand: Merck Millipore Corporation
62-8375-24 Anti-Gemin3, clone 12H12; 100 μg 05-1533
model: 62-8375-24
brand: Sigma Aldrich Japan(Millipore)