62-6180-65 25 mm GD/X Syringe Filter (934AH 1.5 μm) 1 Pack (150 Pieces) 6892-2515
Analyzer, Testing Equipment

62-6180-65 25 mm GD/X Syringe Filter (934AH 1.5 μm) 1 Pack (150 Pieces) 6892-2515

model: 62-6180-65
brand: Cytiva (Whatman)

Product Description

Product Model: 62-6180-65Product Brand: Cytiva (Whatman […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 62-6180-65
Product Brand: Cytiva (Whatman)

Features

  • Does not clog easily compared to general syringe filters and can filter 3~7 times the amount
  • Three-layer prefilter efficiently removes unwanted particles
  • Whatman GMF150 (double layer structure) and GF/F prefilter prevent clogging
  • Syringe filter developed for filtration of solutions containing a large amount of susp***ed particles.
  • As a prefilter, GMF150 (double layer structure) and GF/F of glass fiber filter paper are built in. With this pre-filter, GD/X can filter samples that are difficult to filter with conventional filters by applying light force with your hands without worrying about contamination.
  • Note)Only for test and research purposes.
  • Built-in glass fiber filter paper of each grade instead of membrane. The pre-filter is only GMF150, and there is no GF/F. The pore size is indicated by the particle retention capacity.
  • 934AH= Fiberglass

Spec

  • Housing Material: Polypropylene (Uncolored)
  • Filtration area: 4.6 cm2
  • Voltage: 75psi (5.2 bar)
  • Residual liquid volume: 1.4 mL before air purge, about 250 μl after air purge
  • Dimensions: 20.8 mmx29.8mm
  • Weight: about 3g
  • Flow direction: Sample must be injected from the inlet side.
  • Inlet: Female Luer Lock
  • outlets: male lures
  • Sterilization: Autoclavable. 20 minutes at 121°C, 15psi
  • Glass Fiber: 100% Borosilicate
  • Prefilter: GMF150 (10μm: 1 μm), GF/F (0.7 μm)
  • Note)Pre-filter borosilicate glass fibers are physically and chemically stable, but alkaline components may leach into aqueous solutions. Biological samples that are sensitive to pH can be affected by the elution of trace alkali components.

Related product recommendations

You may also be interested in the following products

62-8514-56 Anti-CD8a (Mo***), APC-Cy7, clone 53-6.7 Antibody MABF1537
Analyzer, Testing Equipment

62-8514-56 Anti-CD8a (Mo***), APC-Cy7, clone 53-6.7 Antibody MABF1537

model: 62-8514-56 brand: Sigma Aldrich Japan(Millipore)
61-6971-29 x Axis Aluminum Crossed Roller Stage Size 100 x 100mm TAM-1001C
Analyzer, Testing Equipment
62-8350-81 Opticap Sterile XL03 Millipore Express SHR with prefilter 0.5 + 0.1μm 9/16 in. HB/HB; 3/Pk KHVES03HH3
Analyzer, Testing Equipment
61-0341-89 Ethyl 4-Toluenesulfonate for Synthesis 808332 500G 8.08332.0500
Analyzer, Testing Equipment