Analyzer, Testing Equipment
61-6882-41 Cold Filter CLDF-50S
Product Description
Product Model: 61-6882-41Product Brand: SIGMAKOKI CO., […]
Contact Us
Product Details
Product Model: 61-6882-41
Product Brand: SIGMAKOKI CO., LTD.
Features
- Tungsten lamps and halogen lamps emit hot rays (infrared rays) along with visible light, which can raise the temperature of the irradiator.
- A cold filter transmits visible light and attenuates infrared light, thereby preventing the temperature of the irradiator from rising.
- By combining the rapid decay of transmittance from the visible to the near-infrared, which is characteristic of dielectric multilayer mirrors, with the high absorptivity on the long wavelength side of the infrared (1000~2000 nm), which is characteristic of hot-wire absorption filters, the entire visible light region can be transmitted and infrared light can be efficiently blocked.
- It can also be ***d as a powerful infrared cut filter for CCD cameras.
- This filter prevents infrared light from appearing in the image.
- It can also be ***d in biomedical observation microscopes where you do not want the temperature of the specimen to change due to illumination.
- * If there is light incident at an angle from an angle to the filter, the transmittance will decrease on the longer wavelength side of the visible range.
- Placing the filter near a light source such as a lamp can ca*** sudden temperature changes due to infrared absorption, which can damage the filter.
- * There is no visible anti-reflection coat on the back of the cold filter.
- * For this reason, absorption by the hot-wire absorption filter and backside reflection (4%) can ca*** loss of 20% or less.
Spec
-
[
common specification]
- Material: Heat absorbing glass
- Incident angle: 0°
- Adaptive wavelength: 400 - 2000nm (block 900nm or more)
- Scratch - dig: 60?40
- Effective diameter: Circle inscribed to 90% of outer dimensions of square
- [Individual specification]
- Transmittance band wavelength (0 degree incidence): 400 - 600nm
- Transmittance band transmittance rate (0 degree incidence): >80%
- Cut-off band wavelength (0 degree incidence): 800 - 2000nm
- Cut-off band transmittance rate (0 degree incidence): <10%
- Half wavelength (50%): 700±20nm
- RoHS conform product
Related product recommendations
You may also be interested in the following products
62-8419-37 α-D-Galactose-1-phosphate, Dipotassium Salt 345646-100MG
model: 62-8419-37
brand: CBC(Merck)
61-0359-77 [Discontinued]Benzothiazole for Synthesis 820141 1L 8.20141.1000
model: 61-0359-77
brand: Merck Millipore Corporation
67-4600-95 CRS GC Septa BTO (Old HT Grade) 17 mm, 24 pcs 0418990
model: 67-4600-95
brand: SGE Analytical Science
61-0319-42 Lichrocart(R) 150-4.6 Lichrospher(R) RP-8 (5 μm) HPLC Cartridge 150635 1ST 1.50635.0001
model: 61-0319-42
brand: Merck Millipore Corporation