61-6882-24 Heat Absorbing Filter 573nm HAF-50S-15H
Analyzer, Testing Equipment

61-6882-24 Heat Absorbing Filter 573nm HAF-50S-15H

model: 61-6882-24
brand: SIGMAKOKI CO., LTD.

Product Description

Product Model: 61-6882-24Product Brand: SIGMAKOKI CO., […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-6882-24
Product Brand: SIGMAKOKI CO., LTD.

Features

  • Light sources such as halogen lamps and xenon lamps contain strong thermal (infrared) radiation in addition to visible light.
  • Use to extract visible light from these lamps that is not affected by heat radiation.
  • By blocking light in the wide wavelength range from the near infrared to the far infrared, the temperature rise ca***d by radiant heat can be suppressed.
  • In an optical system such as a microscope, when the light of a lamp is collected at a single point, the temperature of the sample is prevented from being abnormally high by blocking the heat rays.
  • Beca*** of the high transmittance in the visible range, the lamp does not feel dark when the filter is transmitted.
  • If the filter is placed close to a light source, the filter may break due to sudden temperature changes.
  • If the filter is subjected to heat strengthening treatment, the filter will not break easily even if the temperature rises.
  • * Cannot be ***d for high-power laser or high-energy pulse laser in the absorption wavelength range.
  • * Anti-reflection coat is not applied on both sides.
  • * Reflected light from the front and back ca***s a transmittance loss of about 10%.
  • * To ensure sufficient absorption of infrared rays, there is absorption at the long wavelength side of the visible range.
  • * This ca***s the filter's transmission color to appear cyan (light cyan).

Spec

  • Average transmittance (visible zone): >75%
  • Transmission range *** wavelength: 573nm
  • Transmittance limit wavelength: 701±10nm
  • Long-wavelength side *** wavelength: 867nm
  • Long-wavelength side *** transmittance: <0.5%
  • Average transmittance (long-wavelength side *** to 2000nm): <0.1%
  • RoHS conform product

Related product recommendations

You may also be interested in the following products

61-0332-54 Cystaminium Dichloride for Synthesis 802834 25G 8.02834.0025
Analyzer, Testing Equipment
62-8405-76 ACA 104550-25MG
Analyzer, Testing Equipment

62-8405-76 ACA 104550-25MG

model: 62-8405-76 brand: CBC(Merck)
62-8525-57 Anti-TNF-alpha induced protein 6 (TSG-6), clone NG3; 100 μg MABT108
Analyzer, Testing Equipment
3-3484-02 Liquid Medium for Sterility Test Tube Thioglycolate Liquid Medium 1.46220.0100
Analyzer, Testing Equipment