61-6879-38 Absorptive Neutral Density Filter (Visible・Mount Type) φ25mm Visible Transmittance 0.1±0.07% MAN-25-0.1
Analyzer, Testing Equipment

61-6879-38 Absorptive Neutral Density Filter (Visible・Mount Type) φ25mm Visible Transmittance 0.1±0.07% MAN-25-0.1

model: 61-6879-38
brand: SIGMAKOKI CO., LTD.

Product Description

Product Model: 61-6879-38Product Brand: SIGMAKOKI CO., […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-6879-38
Product Brand: SIGMAKOKI CO., LTD.

Features

  • A filter with a frame for dimming visible light.
  • Since it is an absorption type, stray light due to reflection is small, and the wavelength characteristic of transmitted light does not change significantly due to dimming.
  • Since the transmittance is finely divided, the light can be dimmed to various light levels.
  • Furthermore, by combining multiple filters, subtle light adjustment is possible.
  • A frame is attached to the filter so it can be fixed to the filter holder (FH).
  • There is no filter holder for frame diameter φ30 mm.
  • Use the lens holder (LHF-30 S).
  • If an absorbent fixed ND filter is placed near a light source, the filter may break due to sudden temperature changes.
  • If the filter is subjected to heat strengthening treatment, the filter will not break easily even if the temperature rises.
  • If the filter is thermally tempered, the dimension will be large and may exceed the tolerance range.
  • * Cannot be ***d for high power laser.
  • * There is a risk of damage if ***d.
  • * Use a reflective ND filter (FND) for high power laser.
  • * The transmittance wavelength characteristics vary dep***ing on the manufacturing lot.
  • * In particular, the wavelength characteristics outside the applicable wavelength may differ greatly dep***ing on the manufacturing lot.
  • * Use a reflective filter (FND) if the wavelength range is wider than the specified wavelength range.
  • * The ND filter does not have an anti-reflection coat, so the reflection is about 4%.

Spec

  • [

    common specification]
  • Material: Optical glass (including optical absorption material)
  • Adaptive wavelength: 400 - 700nm
  • [Individual specification]
  • Frame outer diameter φD: φ25mm
  • Effective diameter φA: φ17mm
  • Visible transmittance: 0.1±0.07%
  • RoHS conform product

Related product recommendations

You may also be interested in the following products

62-8462-21 [Discontinued]Anti-Xrcc1 ABE559
Analyzer, Testing Equipment

62-8462-21 [Discontinued]Anti-Xrcc1 ABE559

model: 62-8462-21 brand: Sigma Aldrich Japan(Millipore)
62-8446-56 Anti-GABA B Receptor R2;100 μL AB2255
Analyzer, Testing Equipment

62-8446-56 Anti-GABA B Receptor R2;100 μL AB2255

model: 62-8446-56 brand: Sigma Aldrich Japan(Millipore)
62-8461-44 [Discontinued]Anti-BCL-11A ABE401
Analyzer, Testing Equipment

62-8461-44 [Discontinued]Anti-BCL-11A ABE401

model: 62-8461-44 brand: Sigma Aldrich Japan(Millipore)
62-8536-62 Purospher(R) STAR RP-8 ***capped (5µm) Hibar(R) HR 150-3 UHPLC column 1.50644.0001
Analyzer, Testing Equipment