Spec

  • Filtration area, cm

    2

    : 700
  • Filtration area, m

    2

    : 0.07
  • Diameter, cm (inch): 12.5 (4.9)
  • Length, Inch (cm): 2 (5)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Cellulose mixed ester
  • Housing: Polypropylene
  • Filter brand name: Milligard
  • Format: Double Layer
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Substitute: KWSCL4FF3
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange
  • Quantity/box: 3
  • Overview: Opticap XL2 Milligard low protein absorption 1.2/0.5μm 3/4in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Nominal bore diameter, μm: 1.2 / 0.5
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): 345 (50) @ 25


    °C
  • Sterilization: Autoclave sterilization 3 times for 30 minutes at 121℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 60


    mg per capsule after a 1


    L flush and 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Conform to USP Oxidizable Substances Test after flashing with next water ?1L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8373-63 Anti-GSK3α/β; 100 μL 05-903
Analyzer, Testing Equipment

62-8373-63 Anti-GSK3α/β; 100 μL 05-903

model: 62-8373-63 brand: Sigma Aldrich Japan(Millipore)
62-8514-04 Anti-Ly-6G (mo***), clone RB6-8C5, biotin conjugate Antibody MABF1479
Analyzer, Testing Equipment
62-8387-31 Anti-acetylated-Src (Lys430); 100 μg 07-1285
Analyzer, Testing Equipment

62-8387-31 Anti-acetylated-Src (Lys430); 100 μg 07-1285

model: 62-8387-31 brand: Sigma Aldrich Japan(Millipore)