61-0251-43 Opticap XL4 Durapore 0.1μm 3/4In. TC-9/16In. HB; 3/Pk 3 x 1ST KVVLA04FH3
Analyzer, Testing Equipment

61-0251-43 Opticap XL4 Durapore 0.1μm 3/4In. TC-9/16In. HB; 3/Pk 3 x 1ST KVVLA04FH3

model: 61-0251-43
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0251-43Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0251-43
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.19
  • Filter bore diameter, μm: 0.1
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, Inch (cm): 4 (10)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange/14mm (9/16in.) hose port
  • Quantity/box: 3
  • Overview: Opticap XL4 Durapore 0.1μm 3/4in. TC-9/16in. HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    7.5mL/min at 390kPa (56psig) wetted with water
  • Bubble point, 23 °C:


    483kPa (70psig) water-wet and air
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 10


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

2-8904-11 Smear Test Medium UV Light Stand CST01
Analyzer, Testing Equipment
62-8469-67 Anti-phospho-DBC1 (Thr454) ABS218
Analyzer, Testing Equipment

62-8469-67 Anti-phospho-DBC1 (Thr454) ABS218

model: 62-8469-67 brand: Sigma Aldrich Japan(Millipore)
62-8502-41 Anti-Clathrin Heavy Chain Antibody, clone 6F10.1 MABC580
Analyzer, Testing Equipment

62-8502-41 Anti-Clathrin Heavy Chain Antibody, clone 6F10.1 MABC580

model: 62-8502-41 brand: Sigma Aldrich Japan(Millipore)
62-8501-91 Anti-Folliculin (FLCN), clone 8D9.2 MABC288
Analyzer, Testing Equipment

62-8501-91 Anti-Folliculin (FLCN), clone 8D9.2 MABC288

model: 62-8501-91 brand: Sigma Aldrich Japan(Millipore)