61-0251-41 Opticap XLT30 Durapore 0.1μm 1-1/2In. TC/TC; 1/Pk 1ST KVVLA3TTT1
Analyzer, Testing Equipment

61-0251-41 Opticap XLT30 Durapore 0.1μm 1-1/2In. TC/TC; 1/Pk 1ST KVVLA3TTT1

model: 61-0251-41
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0251-41Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0251-41
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 2.07
  • Filter bore diameter, μm: 0.1
  • Length, cm (inch): 30
  • Length, Inch (cm): 30 (75)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XLT30 Durapore 0.1μm 1-1/2in. TC/TC
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    60mL/min at 390kPa (56psig) water-wet
  • Bubble point, 23 °C:


    483kPa (70psig) water-wet and air
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 3L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0195-35 Nylon Net Filter Disc Hydrophilic 120μm 47mm 100/Pk 100PK NY2H04700
Analyzer, Testing Equipment
62-8438-06 γ-Secretase Inhibitor XII 565773-5MG
Analyzer, Testing Equipment

62-8438-06 γ-Secretase Inhibitor XII 565773-5MG

model: 62-8438-06 brand: CBC(Merck)
62-8494-06 Anti-Fibrillin (Pan), clone 689; 100 μg MAB2641
Analyzer, Testing Equipment

62-8494-06 Anti-Fibrillin (Pan), clone 689; 100 μg MAB2641

model: 62-8494-06 brand: Sigma Aldrich Japan(Millipore)
61-6985-75 Laser Instrument Manager Sign 813-26
Analyzer, Testing Equipment

61-6985-75 Laser Instrument Manager Sign 813-26

model: 61-6985-75 brand: SIGMAKOKI CO., LTD.