61-0251-41 Opticap XLT30 Durapore 0.1μm 1-1/2In. TC/TC; 1/Pk 1ST KVVLA3TTT1
Analyzer, Testing Equipment

61-0251-41 Opticap XLT30 Durapore 0.1μm 1-1/2In. TC/TC; 1/Pk 1ST KVVLA3TTT1

model: 61-0251-41
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0251-41Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0251-41
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 2.07
  • Filter bore diameter, μm: 0.1
  • Length, cm (inch): 30
  • Length, Inch (cm): 30 (75)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XLT30 Durapore 0.1μm 1-1/2in. TC/TC
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    60mL/min at 390kPa (56psig) water-wet
  • Bubble point, 23 °C:


    483kPa (70psig) water-wet and air
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 3L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

3-7484-01 Square Open Field (For Mo***) MSQ-10
Analyzer, Testing Equipment
61-0202-59 Milliflex TGE Agar Filled Medium Cassette 48 x 1ST MXSMTGE48
Analyzer, Testing Equipment
62-8473-38 Anti-Biglycan Antibody ABT271
Analyzer, Testing Equipment

62-8473-38 Anti-Biglycan Antibody ABT271

model: 62-8473-38 brand: Sigma Aldrich Japan(Millipore)
62-8347-60 Opticap Sterile XL10 Express SHF 0.2μm 9/16inHB/HB 1/Pk KGEPS10HH1
Analyzer, Testing Equipment