61-0251-39 Opticap XLT30 Durapore 0.1μm 5/8In. HB/HB; 1/Pk 1ST KVVLA3THH1
Analyzer, Testing Equipment

61-0251-39 Opticap XLT30 Durapore 0.1μm 5/8In. HB/HB; 1/Pk 1ST KVVLA3THH1

model: 61-0251-39
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0251-39Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0251-39
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 2.07
  • Filter bore diameter, μm: 0.1
  • Length, cm (inch): 30
  • Length, Inch (cm): 30 (75)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 16mm (5/8in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT30 Durapore 0.1μm 5/8in. HB/HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    60mL/min at 390kPa (56psig) water-wet
  • Bubble point, 23 °C:


    483kPa (70psig) water-wet and air
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 3L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8371-03 Anti-Rac1 Antibody, clone 23A8, Alexa Fluor(R) 647 Conjugate 05-389-AF647
Analyzer, Testing Equipment
61-6428-19 [Discontinued]COL-ANAL DB PFP PROPYL 100X4.6X3μm N9303897
Analyzer, Testing Equipment
64-9674-90 Glass Set CP Type -300, 300 deg. C Type, 1000 mL 054330-3001
Analyzer, Testing Equipment

64-9674-90 Glass Set CP Type -300, 300 deg. C Type, 1000 mL 054330-3001

model: 64-9674-90 brand: SIBATA SCIENTIFIC TECHNOLOGY LTD.
61-0306-29 Fluorescence Indicator F254 109182 50G 1.09182.0050
Analyzer, Testing Equipment

61-0306-29 Fluorescence Indicator F254 109182 50G 1.09182.0050

model: 61-0306-29 brand: Merck Millipore Corporation