61-0251-37 Opticap XLT20 Durapore 0.1μm 1-1/2In. TC/TC; 1/Pk 1ST KVVLA2TTT1
Analyzer, Testing Equipment

61-0251-37 Opticap XLT20 Durapore 0.1μm 1-1/2In. TC/TC; 1/Pk 1ST KVVLA2TTT1

model: 61-0251-37
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0251-37Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0251-37
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 1.38
  • Filter bore diameter, μm: 0.1
  • Length, cm (inch): 20
  • Length, Inch (cm): 20 (50)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XLT20 Durapore 0.1μm 1-1/2in. TC/TC
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    40mL/min at 390kPa (56psig) water-wet
  • Bubble point, 23 °C:


    483kPa (70psig) water-wet and air
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 50


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 2L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8519-69 Anti-GLAST Antibody, clone 8C11.1 MABN794
Analyzer, Testing Equipment

62-8519-69 Anti-GLAST Antibody, clone 8C11.1 MABN794

model: 62-8519-69 brand: Sigma Aldrich Japan(Millipore)
61-0219-76 [Discontinued]Polysep II Cart Filt 10In. 1.0/0.2μm Code F 3/Pk 3 x 1ST CGW3F1E03
Analyzer, Testing Equipment
61-0387-36 [Discontinued]Fmoc-Orn(Ivdde)-OH 852088 5G 8520880005
Analyzer, Testing Equipment

61-0387-36 [Discontinued]Fmoc-Orn(Ivdde)-OH 852088 5G 8520880005

model: 61-0387-36 brand: Merck Millipore Corporation
61-6430-11 [Discontinued]COL-ELITE-502-105m-.53mm-3μm N9316190
Analyzer, Testing Equipment