61-0250-76 Opticap Gamma Compatible XLT30 Durapore 0.22μm GC 5/8In HB/HB 1/Pk 1ST KVGLG3THH1
Analyzer, Testing Equipment

61-0250-76 Opticap Gamma Compatible XLT30 Durapore 0.22μm GC 5/8In HB/HB 1/Pk 1ST KVGLG3THH1

model: 61-0250-76
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-76Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-76
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 2.17
  • Length from inlet to outlet, cm (inch): 19.8 (7.8)
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 87.1 (34.3)
  • Length, Inch (cm): 30 (75)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Gamma compatible polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Form: Capsule
  • Connection, Inlet/outlet: 16mm (5/8in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT30 Durapore 0.22μm gamma compatible 5/8in. HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    42mL/min at 280kPa (40psig) wetted with water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 3L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

63-6527-58 BD BBL (TM) Skillow Medium 20 sheets 252111
Analyzer, Testing Equipment

63-6527-58 BD BBL (TM) Skillow Medium 20 sheets 252111

model: 63-6527-58 brand: BD (Becton, Dickinson and Company)
62-8536-53 Purospher(R) STAR RP-18 ***capped (5µm) Hibar(R) RT 100-3 HPLC column 1.50612.0001
Analyzer, Testing Equipment
4-481-01 Headspace Vial 10mL 100 Pieces HSV10F
Analyzer, Testing Equipment

4-481-01 Headspace Vial 10mL 100 Pieces HSV10F

model: 4-481-01 brand: AS ONE Corporation
61-0366-09 [Discontinued]Biphenyl-2-Ol for Synthesis 821007 100G 8.21007.0100
Analyzer, Testing Equipment