61-0250-72 Opticap Gamma Compatible XLT20 Durapore 0.22μm GC 1.5In TC/TC 1/Pk 1ST KVGLG2TTT1
Analyzer, Testing Equipment

61-0250-72 Opticap Gamma Compatible XLT20 Durapore 0.22μm GC 1.5In TC/TC 1/Pk 1ST KVGLG2TTT1

model: 61-0250-72
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-72Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-72
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 1.4
  • Length from inlet to outlet, cm (inch): 15.2 (6.0)
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 62.5 (24.6)
  • Length, Inch (cm): 20 (50)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Gamma compatible polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XLT20 Durapore 0.22μm gamma compatible -1/8in. HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    28mL/min at 280kPa (40psig) wetted with water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 50


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 2L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8369-05 Anti-Folr4 (Folate receptor 4), clone 5E12.2; 100 μg 04-968
Analyzer, Testing Equipment

62-8369-05 Anti-Folr4 (Folate receptor 4), clone 5E12.2; 100 μg 04-968

model: 62-8369-05 brand: Sigma Aldrich Japan(Millipore)
3-6692-01 Biological Microscope with EC Plan Lens, Binocular 40 - 1000 x MP38B
Analyzer, Testing Equipment
62-8482-12 Fibrin In Vitro Angiogenesis Assay; 1 kit ECM630
Analyzer, Testing Equipment

62-8482-12 Fibrin In Vitro Angiogenesis Assay; 1 kit ECM630

model: 62-8482-12 brand: Sigma Aldrich Japan(Millipore)
62-8358-96 Lynx S2S Connector Set, non-sterile; 1Female, 1Male SSCSHB3A01
Analyzer, Testing Equipment

62-8358-96 Lynx S2S Connector Set, non-sterile; 1Female, 1Male SSCSHB3A01

model: 62-8358-96 brand: Sigma Aldrich Japan(Millipore)