61-0250-71 Opticap Gamma Compatible XLT20 Durapore 0.22μm GC 1.5In TC-5/8In HB 1/Pk 1ST KVGLG2TTH1
Analyzer, Testing Equipment

61-0250-71 Opticap Gamma Compatible XLT20 Durapore 0.22μm GC 1.5In TC-5/8In HB 1/Pk 1ST KVGLG2TTH1

model: 61-0250-71
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-71Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-71
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 1.4
  • Length from inlet to outlet, cm (inch): 17.5 (6.9)
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 62.5 (24.6)
  • Length, Inch (cm): 20 (50)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Gamma compatible polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange/16mm (5/8in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT20 Durapore 0.22μm gamma compatible 1-1/2in. TC-5/8in. HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    28mL/min at 280kPa (40psig) wetted with water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 50


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 2L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0380-66 [Discontinued]2-Aminobenzophenone for Synthesis 841771 10G 8.41771.0010
Analyzer, Testing Equipment
2-6538-01 [Discontinued]HPLC Column 8105
Analyzer, Testing Equipment
61-0401-60 [Discontinued]Fmoc-Pal AM Resin 855133 1G 8551330001
Analyzer, Testing Equipment

61-0401-60 [Discontinued]Fmoc-Pal AM Resin 855133 1G 8551330001

model: 61-0401-60 brand: Merck Millipore Corporation
61-0196-06 UF Discs PLTK Ultracel RC 30kDa 25mm 10/Pk 10PK PLTK02510
Analyzer, Testing Equipment

61-0196-06 UF Discs PLTK Ultracel RC 30kDa 25mm 10/Pk 10PK PLTK02510

model: 61-0196-06 brand: Merck Millipore Corporation