Product Model: 61-0250-56
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.35
  • Filter bore diameter, μm: 0.22
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, Inch (cm): 5 (12.5)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange/14mm (9/16in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XL5 Durapore 0.22μm TC/HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    6.6mL/min at 280kPa (40psig) water-wet
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 15


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0192-67 Nylon Net Filter Disc Hydrophilic 10μm 25mm 100/Pk 100PK NY1002500
Analyzer, Testing Equipment
61-0248-03 Opticap XL5 Polygard-Cr 3.0μm 9/16In. HB/HB 1/Pk 1ST KR03A05HH1
Analyzer, Testing Equipment
61-0195-10 Millex-Ap AP20 Prefer 50mm Non-Ster 10/Pk 10PK SLAP05010
Analyzer, Testing Equipment

61-0195-10 Millex-Ap AP20 Prefer 50mm Non-Ster 10/Pk 10PK SLAP05010

model: 61-0195-10 brand: Merck Millipore Corporation
61-6431-24 [Discontinued]COL-ELITE XLB-30m-.25mm-1.0μm N9316485
Analyzer, Testing Equipment