61-0250-55 Opticap XL5 Durapore 0.22μm 9/16In. HB/HB; 1/Pk 1ST KVGLA05HH1
Analyzer, Testing Equipment

61-0250-55 Opticap XL5 Durapore 0.22μm 9/16In. HB/HB; 1/Pk 1ST KVGLA05HH1

model: 61-0250-55
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-55Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-55
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.35
  • Filter bore diameter, μm: 0.22
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, Inch (cm): 5 (12.5)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 14mm (9/16in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XL5 Durapore 0.22μm 9/16in. HB/HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    6.6mL/min at 280kPa (40psig) water-wet
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 15


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL

Related product recommendations

You may also be interested in the following products

62-8464-42 Anti-TGF-beta Receptor Antibody, type I ABF17-I
Analyzer, Testing Equipment

62-8464-42 Anti-TGF-beta Receptor Antibody, type I ABF17-I

model: 62-8464-42 brand: Sigma Aldrich Japan(Millipore)
61-4429-83 Viton Seal Screw for Φ25mm 061620-2512A
Analyzer, Testing Equipment

61-4429-83 Viton Seal Screw for Φ25mm 061620-2512A

model: 61-4429-83 brand: SIBATA SCIENTIFIC TECHNOLOGY LTD.
62-8464-67 Anti-ZIP-8 Antibody ABF197
Analyzer, Testing Equipment

62-8464-67 Anti-ZIP-8 Antibody ABF197

model: 62-8464-67 brand: Sigma Aldrich Japan(Millipore)
4-4777-01 stereomicroscope (arm) binocular SZ-3500-AC
Analyzer, Testing Equipment