61-0250-52 Opticap XL4 Durapore 0.22μm 1-1/2In. TC-9/16In. HB; 3/Pk 3 x 1ST KVGLA04TH3
Analyzer, Testing Equipment

61-0250-52 Opticap XL4 Durapore 0.22μm 1-1/2In. TC-9/16In. HB; 3/Pk 3 x 1ST KVGLA04TH3

model: 61-0250-52
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-52Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-52
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.19
  • Filter bore diameter, μm: 0.22
  • Diameter, cm (inch): 12.5 (4.9)
  • Length, Inch (cm): 4 (10)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange/14mm (9/16in.) hose port
  • Quantity/box: 3
  • Overview: Opticap XL4 Durapore 0.22μm TC/HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    5.5mL/min at 280kPa (40psig) wetted with water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 10


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0230-41 Clarigard Cart Filt 10In. 0.2μm Code 7 Sil 1/Pk 1ST D00271S01
Analyzer, Testing Equipment
62-8345-92 Opticap Autoclavable XLT10 Express SHF 0.2μm 1.5in TC/TC 1/Pk KGEPA1TTT1
Analyzer, Testing Equipment
61-0208-99 UF Discs YM100 Ultracel RC 100kDa 63.5mm 10/Pk 10PK 14432
Analyzer, Testing Equipment

61-0208-99 UF Discs YM100 Ultracel RC 100kDa 63.5mm 10/Pk 10PK 14432

model: 61-0208-99 brand: Merck Millipore Corporation
62-8368-72 Anti-phospho-Histone H3 (Ser10), clone MC463; 100 μL 04-817
Analyzer, Testing Equipment

62-8368-72 Anti-phospho-Histone H3 (Ser10), clone MC463; 100 μL 04-817

model: 62-8368-72 brand: Sigma Aldrich Japan(Millipore)