61-0250-39 Opticap XLT20 Durapore 0.22μm 5/8In. HB/HB; 1/Pk 1ST KVGLA2THH1
Analyzer, Testing Equipment

61-0250-39 Opticap XLT20 Durapore 0.22μm 5/8In. HB/HB; 1/Pk 1ST KVGLA2THH1

model: 61-0250-39
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-39Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-39
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 1.38
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 20
  • Length, Inch (cm): 20 (50)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 16mm (5/8in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT20 Durapore 0.22μm 5/8in. HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    26.6mL/min @ 280kPa (40 psig) in water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 50


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 2L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0229-73 Milligard Cart Filt 10In. Code 5 0.5/0.2μm 3/Pk 3 x 1ST CWSS51S03
Analyzer, Testing Equipment
62-8372-42 Anti-ubiquityl-Histone H2A, clone E6C5; 200 μL 05-678
Analyzer, Testing Equipment

62-8372-42 Anti-ubiquityl-Histone H2A, clone E6C5; 200 μL 05-678

model: 62-8372-42 brand: Sigma Aldrich Japan(Millipore)
62-8472-30 Anti-Tensin-3; 100 μg ABT29
Analyzer, Testing Equipment

62-8472-30 Anti-Tensin-3; 100 μg ABT29

model: 62-8472-30 brand: Sigma Aldrich Japan(Millipore)
61-4413-75 Micro Burette Horizontal Type 1 0.15mL 022810-1
Analyzer, Testing Equipment

61-4413-75 Micro Burette Horizontal Type 1 0.15mL 022810-1

model: 61-4413-75 brand: SIBATA SCIENTIFIC TECHNOLOGY LTD.