61-0250-36 Opticap XL2 Durapore 0.22μm 1/4In. NPT/NPT; 3/Pk 3 x 1ST KVGLA02NN3
Analyzer, Testing Equipment

61-0250-36 Opticap XL2 Durapore 0.22μm 1/4In. NPT/NPT; 3/Pk 3 x 1ST KVGLA02NN3

model: 61-0250-36
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-36Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-36
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, cm

    2

    : 900
  • Filtration area, m

    2

    : 0.09
  • Filter bore diameter, μm: 0.22
  • Diameter, cm (inch): 12.5 (4.9)
  • Length, Inch (cm): 2 (5)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Substitute: KVGL04HB3
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 6


    mm (1/4


    in.) NPTM
  • Quantity/box: 3
  • Overview: Opticap XL2 Durapore 0.22μm 1/4in. NPT/NPT
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 10


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

4-891-01 Chromatography Filter Paper No. 51A 100 Pieces 2163020
Analyzer, Testing Equipment
62-8526-23 Anti-CD167a/DDR1 Antibody, clone 5D5 MABT333
Analyzer, Testing Equipment

62-8526-23 Anti-CD167a/DDR1 Antibody, clone 5D5 MABT333

model: 62-8526-23 brand: Sigma Aldrich Japan(Millipore)
62-8379-95 StemSelect(R) Compound E 5.30509.0001
Analyzer, Testing Equipment

62-8379-95 StemSelect(R) Compound E 5.30509.0001

model: 62-8379-95 brand: CBC(Merck)