61-0250-32 Opticap XLT10 Durapore 0.22μm 1-1/2In. TC/TC; 1/Pk 1ST KVGLA1TTT1
Analyzer, Testing Equipment

61-0250-32 Opticap XLT10 Durapore 0.22μm 1-1/2In. TC/TC; 1/Pk 1ST KVGLA1TTT1

model: 61-0250-32
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-32Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-32
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.69
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 10
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XLT10 Durapore 0.22μm 1-1/2in. TC
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    13.3mL/min @ 280kPa (40 psig) in water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 25


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Conform to USP Oxidizable Substances Test after flashing with next water ?1L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0306-41 AzureⅡ(C.I. 52010/52015) For Microscope 109211 10G 1.09211.0010
Analyzer, Testing Equipment
61-0308-13 Formamide for Analysis Emsure(TM) ACS, Reag. pH Eur 109684 2.5L 1.09684.2500
Analyzer, Testing Equipment
61-0386-42 [Discontinued]Fmoc-Nva-OH 852047 5G 8520470005
Analyzer, Testing Equipment

61-0386-42 [Discontinued]Fmoc-Nva-OH 852047 5G 8520470005

model: 61-0386-42 brand: Merck Millipore Corporation
61-0225-33 [Discontinued]Polygard-CR Cart Filt 2In. 100μm Code M Silicone 3/Pk 3 x 1ST CR99M0203
Analyzer, Testing Equipment