Product Model: 61-0249-02
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.32
  • Filter bore diameter, μm: 0.2
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, cm (inch): 21.6 (8.5)
  • Length, Inch (cm): 5 (12.5)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophobicity PTFE
  • Housing: Polypropylene
  • Filter brand name: Aervent
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Vent/drain: 1/4in. hose port with double O-ring seal
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XL5 Aervent 0.2μm 3/4in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    12mL/min at 96.5kPa (14psig) 70//30% IPA/water
  • Hydro-Core test:


    0.38?mL/min @ 260?kPa (38?psig)
  • Bubble point, 23 °C:


    110kPa (16psig) 70/30% IPA/water
  • Maximum input pressure, kPa (psi): 552 (80) @ 23


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 414 (60) at 25℃, intermittent
  • Wettability: Hydrophobicity
  • Sterilization: Autoclave sterilization at 135℃ for 30 minutes for 30 times; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Nitrogen diffusion flow rate, 23 °C:


    5mL/min at 170kPa (25psig) water-wet
  • Total extract: The extractables level was equal to or less than 28


    mg after 24


    hours in a 70/30%


    IPA/water mixture at controlled room temperature.
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

3-9849-01 Manual Stage LS-4047-S1
Analyzer, Testing Equipment

3-9849-01 Manual Stage LS-4047-S1

model: 3-9849-01 brand: CHUO PRECISION INDUSTRIAL Co., Ltd.
62-8384-02 Anti-phospho-SHC Antibody (Tyr239, Tyr240) 07-209-I
Analyzer, Testing Equipment

62-8384-02 Anti-phospho-SHC Antibody (Tyr239, Tyr240) 07-209-I

model: 62-8384-02 brand: Sigma Aldrich Japan(Millipore)
62-8492-63 Anti-Integrin alphaVbeta3, clone LM609; 100 μg MAB1976
Analyzer, Testing Equipment

62-8492-63 Anti-Integrin alphaVbeta3, clone LM609; 100 μg MAB1976

model: 62-8492-63 brand: Sigma Aldrich Japan(Millipore)
62-8531-22 OxyBlot Protein Oxidation Detection Kit; 200 assays S7150
Analyzer, Testing Equipment

62-8531-22 OxyBlot Protein Oxidation Detection Kit; 200 assays S7150

model: 62-8531-22 brand: Sigma Aldrich Japan(Millipore)