61-0247-90 Opticap XL10 Durapore 0.45μm W/O Pref 9/16In. HB/HB 1/Pk 1ST KPHLA10HH1
Analyzer, Testing Equipment

61-0247-90 Opticap XL10 Durapore 0.45μm W/O Pref 9/16In. HB/HB 1/Pk 1ST KPHLA10HH1

model: 61-0247-90
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0247-90Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0247-90
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.69
  • Filter bore diameter, μm: 0.45
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Substitute: KPHL01HB1
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 14mm (9/16in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XL10 Durapore 0.45μm without pre-filter 9/16in. HB/HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    15mL/min at 150kPa (22psig) water-wet
  • Bubble point, 23 °C:


    193kPa (28 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Positive direction - 345 (50) at 25℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 25


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Conform to USP Oxidizable Substances Test after flashing with next water ?1L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0403-38 [Discontinued]H-Asp(OtBU)-H Novasyn(R) TG Resin 856072 5G 8560720005
Analyzer, Testing Equipment
62-8518-78 [Discontinued]Anti-LRAT Antibody, clone M34-P1F10 Cat. No. MABN644 MABN644
Analyzer, Testing Equipment
61-0344-20 Tributyltin Hydride for Synthesis 814109 25mL 8.14109.0025
Analyzer, Testing Equipment

61-0344-20 Tributyltin Hydride for Synthesis 814109 25mL 8.14109.0025

model: 61-0344-20 brand: Merck Millipore Corporation