61-0247-87 Opticap XL5 Durapore 0.45μm W/O Pref 9/16In. HB/HB 1ST KPHLA05HH1
Analyzer, Testing Equipment

61-0247-87 Opticap XL5 Durapore 0.45μm W/O Pref 9/16In. HB/HB 1ST KPHLA05HH1

model: 61-0247-87
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0247-87Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0247-87
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.35
  • Filter bore diameter, μm: 0.45
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, Inch (cm): 5 (12.5)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 14mm (9/16in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XL5 Durapore 0.45μm without pre-filter 9/16in. HB/HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    7.5mL/min at 150kPa (22psig) water-wet
  • Bubble point, 23 °C:


    193kPa (28 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Positive direction - 345 (50) at 25℃ (without pre-filter); reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 15


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8525-06 Anti-TfR1 Antibody, clone 3B82A1 MABS1982
Analyzer, Testing Equipment

62-8525-06 Anti-TfR1 Antibody, clone 3B82A1 MABS1982

model: 62-8525-06 brand: Sigma Aldrich Japan(Millipore)
61-0360-72 Chloride 2-Chloroethyl Ammonium for Synthesis 820265 100G 8.20265.0100
Analyzer, Testing Equipment
62-8506-11 Anti-phospho-RNAPII (Tyr1) Antibody, clone 3D12 Cat. No. MABE350 MABE350
Analyzer, Testing Equipment
61-0320-70 Chromolith Performance Si 100-4.6 Chromolith(R) 151465 1ST 1.51465.0001
Analyzer, Testing Equipment