61-0247-81 Opticap XL4 Durapore 0.45μm W/O Pref 3/4In. TC/TC 3/Pk 3 x 1ST KPHLA04FF3
Analyzer, Testing Equipment

61-0247-81 Opticap XL4 Durapore 0.45μm W/O Pref 3/4In. TC/TC 3/Pk 3 x 1ST KPHLA04FF3

model: 61-0247-81
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0247-81Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0247-81
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.19
  • Filter bore diameter, μm: 0.45
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, Inch (cm): 4 (10)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange
  • Quantity/box: 3
  • Overview: Opticap XL4 Durapore 0.45μm without pre-filter 3/4in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    4.5mL/min at 150kPa (22psig) water-wet
  • Bubble point, 23 °C:


    193kPa (28 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Positive direction - 345 (50) at 25℃ (without pre-filter); reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 10


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8473-92 Anti-Myosin-10/MYH10/Myosin IIB Antibody ABT1340
Analyzer, Testing Equipment

62-8473-92 Anti-Myosin-10/MYH10/Myosin IIB Antibody ABT1340

model: 62-8473-92 brand: Sigma Aldrich Japan(Millipore)
62-8502-64 Anti-KLF4, clone 1E6 MABC631 MABC631
Analyzer, Testing Equipment

62-8502-64 Anti-KLF4, clone 1E6 MABC631 MABC631

model: 62-8502-64 brand: Sigma Aldrich Japan(Millipore)
63-6530-14 BD Difco (TM) Listeria Enrichment Broth 500 g 222220
Analyzer, Testing Equipment

63-6530-14 BD Difco (TM) Listeria Enrichment Broth 500 g 222220

model: 63-6530-14 brand: BD (Becton, Dickinson and Company)
62-8444-95 Anti-Uncoupling Protein 1; 50 μL AB1426
Analyzer, Testing Equipment

62-8444-95 Anti-Uncoupling Protein 1; 50 μL AB1426

model: 62-8444-95 brand: Sigma Aldrich Japan(Millipore)