61-0247-78 Opticap XL2 Durapore 0.45μm W/O Pref 9/16In. HB/HB 3/Pk 3 x 1ST KPHLA02HH3
Analyzer, Testing Equipment

61-0247-78 Opticap XL2 Durapore 0.45μm W/O Pref 9/16In. HB/HB 3/Pk 3 x 1ST KPHLA02HH3

model: 61-0247-78
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0247-78Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0247-78
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, cm

    2

    : 900
  • Filtration area, m

    2

    : 0.09
  • Filter bore diameter, μm: 0.45
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, Inch (cm): 2 (5)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Substitute: SN1M006A6
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 14mm (9/16in.) hose port
  • Quantity/box: 3
  • Overview: Opticap XL2 Durapore 0.45μm without pre-filter 9/16in. HB/HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Bubble point, 23 °C:


    193kPa (28 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Positive direction - 345 (50) at 25℃ (without pre-filter); reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 10


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0201-21 Isopore Disc PC Philic 0.22μm 47mm Wh Pln 100/Pk 100PK GTTP04700
Analyzer, Testing Equipment
62-8349-46 Opticap Sterile XL05 Millipore Express SHC 0.5 + 0.2μm 1-1/2in. TC/TC; 1/Pk KHGES05TT1
Analyzer, Testing Equipment
62-8436-18 Protein Tyrosine Phosphatase Inhibitor IV 540211-10MG
Analyzer, Testing Equipment