61-0247-76 Opticap XL2 Durapore 0.45μm W/O Pref 3/4In. TC/TC 3/Pk 3 x 1ST KPHLA02FF3
Analyzer, Testing Equipment

61-0247-76 Opticap XL2 Durapore 0.45μm W/O Pref 3/4In. TC/TC 3/Pk 3 x 1ST KPHLA02FF3

model: 61-0247-76
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0247-76Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0247-76
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, cm

    2

    : 900
  • Filtration area, m

    2

    : 0.09
  • Filter bore diameter, μm: 0.45
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, Inch (cm): 2 (5)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Stable polypropylene to gamma ray
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange
  • Quantity/box: 3
  • Overview: Opticap XL2 Durapore 0.45μm without pre-filter 3/4in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Bubble point, 23 °C:


    193kPa (28 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Positive direction - 345 (50) at 25℃ (without pre-filter); reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 10


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8466-84 Anti-NIPSNAP3B ABN355
Analyzer, Testing Equipment

62-8466-84 Anti-NIPSNAP3B ABN355

model: 62-8466-84 brand: Sigma Aldrich Japan(Millipore)
61-0320-68 Lichrocart 75-4 Purospher STAR RP-18e (3μm) HPLC Cartridge Kit 151460 1ST 1.51460.0001
Analyzer, Testing Equipment
62-8415-29 InSolution Cyclopamine, V. californicum 239806-5MG
Analyzer, Testing Equipment
61-0196-06 UF Discs PLTK Ultracel RC 30kDa 25mm 10/Pk 10PK PLTK02510
Analyzer, Testing Equipment

61-0196-06 UF Discs PLTK Ultracel RC 30kDa 25mm 10/Pk 10PK PLTK02510

model: 61-0196-06 brand: Merck Millipore Corporation