61-0242-94 Opticap XLT10 Polysep II 1/0.2/0.1μm 5/8In. HB/HB 1/Pk 1ST KGW1A1THH1
Analyzer, Testing Equipment

61-0242-94 Opticap XLT10 Polysep II 1/0.2/0.1μm 5/8In. HB/HB 1/Pk 1ST KGW1A1THH1

model: 61-0242-94
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0242-94Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0242-94
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.42
  • Length from inlet to outlet, cm (inch): 19.8 (7.8)
  • Length, cm (inch): 37.6 (14.8)
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Borosilicate glass Fiber
  • Vent cap material: Polypropylene
  • Material: Cellulose mixed ester
  • Housing: Polypropylene
  • Format: Triple Layer
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 16mm (5/8in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT10 Polysep II 1.0/0.2/0.1μm 5/8in. HB/HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Nominal bore diameter, μm: 1.0 / 0.2 / 0.1
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): 345 (50) @ 25


    °C
  • Sterilization: Autoclave sterilization 3 times for 30 minutes at 121℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 145


    mg per capsule after a 5


    L flush and 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 5L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8497-70 Anti-Reelin, a.a. 164-189 mreelin, clone 142; 100 μg MAB5366
Analyzer, Testing Equipment

62-8497-70 Anti-Reelin, a.a. 164-189 mreelin, clone 142; 100 μg MAB5366

model: 62-8497-70 brand: Sigma Aldrich Japan(Millipore)
62-8509-29 Anti-TMEM173/STING, clone 1B1.1 MABF223
Analyzer, Testing Equipment

62-8509-29 Anti-TMEM173/STING, clone 1B1.1 MABF223

model: 62-8509-29 brand: Sigma Aldrich Japan(Millipore)
2-9044-19 Substitute Edge No.24 ACM24 SM ACM24SM
Analyzer, Testing Equipment
61-6967-10 X-Axis Steel Stage Size 60 x 60mm TSD-601C
Analyzer, Testing Equipment

61-6967-10 X-Axis Steel Stage Size 60 x 60mm TSD-601C

model: 61-6967-10 brand: SIGMAKOKI CO., LTD.