61-0228-51 Durapore Cart Filt W/Pref 20In. 0.45μm Code 7 3/Pk 3 x 1ST CVHL72TP3
Analyzer, Testing Equipment

61-0228-51 Durapore Cart Filt W/Pref 20In. 0.45μm Code 7 3/Pk 3 x 1ST CVHL72TP3

model: 61-0228-51
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0228-51Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0228-51
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 1.38
  • Filter bore diameter, μm: 0.45
  • Diameter, cm (inch): 6.9 (2.7)
  • Length, Inch (cm): 20 (50)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Cellulose mixed ester
  • Material: Hydrophilic PVDF
  • Code: Code 7
  • Filter brand name: Durapore(R)
  • Brand name: Durapore
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Cartridge
  • Quantity/box: 3
  • Overview: Durapore cartridge filter with pre-filter 20in. 0.45μm code 7
  • Product name: Durapore cartridge filter
  • Air diffusion flow rate, 23 °C:


    30mL/min at 150kPa (22psig) water-wet
  • Cartridge code: Code 7 (2-226) with O-ring/locking tab spear
  • Bubble point, 23 °C:


    193kPa (28 psig) air with water
  • Maximum input pressure, kPa (psi): Forward


    - 5.5 (80) @ 25


    °C; 1.7 (25) @ 80


    °C; 0.35 (5) @ 135


    °C; Reverse


    - 3.5 (50) @ 25


    °C
  • Maximum differential pressure, kPa (psid): Forward


    - 552 (80) @ 25


    ℃; 172 (25) @ 80


    ℃; 34 (5) @ 135


    ℃; Backward


    - 345 (50) @ 25


  • Wettability: Hydrophilic
  • Sterilization: SIP sterilization 10 times for 30 minutes at 121℃ or autoclave sterilization 10 times for 60 minutes at 121℃
  • Total extract: The extractables level was equal to or less than 45


    mg per 10-inch cartridge after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 2L

Related product recommendations

You may also be interested in the following products

62-8468-14 Anti-C9ORF72/C9RANT (Poly-PR) ABN1354
Analyzer, Testing Equipment

62-8468-14 Anti-C9ORF72/C9RANT (Poly-PR) ABN1354

model: 62-8468-14 brand: Sigma Aldrich Japan(Millipore)
62-8449-74 Anti-Synuclein, alpha; 50 μg AB5336P
Analyzer, Testing Equipment

62-8449-74 Anti-Synuclein, alpha; 50 μg AB5336P

model: 62-8449-74 brand: Sigma Aldrich Japan(Millipore)
61-0226-17 Polygard-CR Cart Filt 20In. 100μm Code 7 Silicone 6/Pk 6 x 1ST CR9972006
Analyzer, Testing Equipment
4-908-13 Glass Filter Paper GA-100 100 Pieces 36281021
Analyzer, Testing Equipment