61-0228-45 Durapore Cart Filt W/Pref 30In. 0.45μm Code 0 3/Pk 3 x 1ST CVHL03TP3
Analyzer, Testing Equipment

61-0228-45 Durapore Cart Filt W/Pref 30In. 0.45μm Code 0 3/Pk 3 x 1ST CVHL03TP3

model: 61-0228-45
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0228-45Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0228-45
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 2.07
  • Filter bore diameter, μm: 0.45
  • Diameter, cm (inch): 6.9 (2.7)
  • Length, Inch (cm): 30 (75)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Cellulose mixed ester
  • Material: Hydrophilic PVDF
  • Code: Code 0
  • Filter brand name: Durapore(R)
  • Brand name: Durapore
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Cartridge
  • Quantity/box: 3
  • Overview: Durapore cartridge filter with pre-filter 30in. 0.45μm code 0
  • Product name: Durapore cartridge filter
  • Air diffusion flow rate, 23 °C:


    45mL/min at 150kPa (22psig) water-wet
  • Cartridge code: Code 0 (2-222) O-ring
  • Bubble point, 23 °C:


    193kPa (28 psig) air with water
  • Maximum input pressure, kPa (psi): Forward


    - 5.5 (80) @ 25


    °C; 1.7 (25) @ 80


    °C; 0.35 (5) @ 135


    °C; Reverse


    - 3.5 (50) @ 25


    °C
  • Maximum differential pressure, kPa (psid): Forward


    - 552 (80) @ 25


    ℃; 172 (25) @ 80


    ℃; 34 (5) @ 135


    ℃; Backward


    - 345 (50) @ 25


  • Wettability: Hydrophilic
  • Sterilization: SIP sterilization 10 times for 30 minutes at 121℃ or autoclave sterilization 10 times for 60 minutes at 121℃
  • Total extract: The extractables level was equal to or less than 45


    mg per 10-inch cartridge after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 3L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0292-41 [Discontinued]Eosin Y-Solution 0.5% Alcoholic for Microscopy 102439 2.5L 1.02439.2500
Analyzer, Testing Equipment
61-4429-99 Filter Holder Set Support Screen  without Suction Bottle Φ47mm 061630-4702
Analyzer, Testing Equipment
62-8387-81 Anti-JAK1; 100 μg 07-1485
Analyzer, Testing Equipment

62-8387-81 Anti-JAK1; 100 μg 07-1485

model: 62-8387-81 brand: Sigma Aldrich Japan(Millipore)
62-8375-03 [Discontinued]Anti-GβL/mLST8, clone 3E1.2; 100 μg 05-1482
Analyzer, Testing Equipment