61-0227-99 Durapore Cart Filt W/Pref 10In. 0.65μm Code 0 3/Pk 3 x 1ST CVDR01TP3
Analyzer, Testing Equipment

61-0227-99 Durapore Cart Filt W/Pref 10In. 0.65μm Code 0 3/Pk 3 x 1ST CVDR01TP3

model: 61-0227-99
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0227-99Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0227-99
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.69
  • Filter bore diameter, μm: 0.65
  • Diameter, cm (inch): 6.9 (2.7)
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Cellulose mixed ester
  • Material: Hydrophilic PVDF
  • Code: Code 0
  • Filter brand name: Durapore(R)
  • Brand name: Durapore
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Cartridge
  • Quantity/box: 3
  • Overview: Durapore cartridge filter with pre-filter 10in. 0.65μm code 0
  • Product name: Durapore cartridge filter
  • Air diffusion flow rate, 23 °C:


    10mL/min at 62kPa (9psig) water-wet
  • Cartridge code: Code 0 (2-222) O-ring
  • Bubble point, 23 °C:


    965


    mbar (14


    psig) air with water
  • Maximum input pressure, kPa (psi): Forward


    - 5.5 (80) @ 25


    °C; 1.7 (25) @ 80


    °C; 0.35 (5) @ 121


    °C; Reverse


    - 1.7 (25) @ 25


    °C
  • Maximum differential pressure, kPa (psid): Positive direction - 552 (80) at 25℃; 172 (25) at 80℃; 34 (5) at 121℃; reverse direction - 172 (25) at 25℃
  • Wettability: Hydrophilic
  • Sterilization: In-line steam sterilization 8 times for 30 minutes at 121℃ or autoclave sterilization 8 times for 60 minutes at 121℃
  • Total extract: The extractables level was equal to or less than 45


    mg per 10-inch cartridge after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Conform to USP Oxidizable Substances Test after flashing with next water ?1L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0207-55 Nylon Net Filter Roll Hydrophilic 160μm 30cmx3m 1/Pk 1PK NY6H00010
Analyzer, Testing Equipment
62-8528-61 EZ-Float(TM)Tissue Mounting Reagent 100X NS350-5ML
Analyzer, Testing Equipment

62-8528-61 EZ-Float(TM)Tissue Mounting Reagent 100X NS350-5ML

model: 62-8528-61 brand: Sigma Aldrich Japan(Millipore)