61-0219-06 Charged Durapore Cart 10In. 0.22μm Code 0 1/Pk 1ST CCGL01TP1
Analyzer, Testing Equipment

61-0219-06 Charged Durapore Cart 10In. 0.22μm Code 0 1/Pk 1ST CCGL01TP1

model: 61-0219-06
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0219-06Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0219-06
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.69
  • Filter bore diameter, μm: 0.22
  • Diameter, cm (inch): 6.9 (2.7)
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Material: Charged PVDF
  • Code: Code 0
  • Filter brand name: Durapore(R)
  • Brand name: Durapore
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Cartridge
  • Quantity/box: 1
  • Overview: Charged Durapore cartridge 10


    in. 0.22


    μm code 0
  • Product name: Charged Durapore cartridge filter
  • Air diffusion flow rate, 23 °C:


    10


    mL/min @ 210


    kPa (30


    psig) wetted with water
  • Cartridge code: Code 0 (2-222) O-ring
  • Bubble point, 23 °C:


    276


    kPa (40


    psig) wetted with water and air
  • Maximum input pressure, kPa (psi): Forward


    - 5.5 (80) @ 25


    ℃; 1.7 (25) @ 80


    ℃; 0.35 (5) @ 135


    ℃; Backward


    - 3.5 (50) @ 25


  • Maximum differential pressure, kPa (psid): Forward


    - 552 (80) @ 25


    ℃; 172 (25) @ 80


    ℃; 34 (5) @ 135


    ℃; Backward


    - 345 (50) @ 25


  • Flow rate, L/min: 45 @ 400


    mbar ΔP
  • Wettability: Hydrophilic
  • Sterilization: Inline steam sterilization of 135℃ for 30 minutes, 10 times
  • Total extract: The extractables level was equal to or less than 20


    mg per 10-inch cartridge after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8381-36 Anti-Phosphotyrosine 06-427
Analyzer, Testing Equipment

62-8381-36 Anti-Phosphotyrosine 06-427

model: 62-8381-36 brand: Sigma Aldrich Japan(Millipore)
62-8388-56 Anti-phospho-FOXO1 (Thr24); 100 μg 7-26
Analyzer, Testing Equipment

62-8388-56 Anti-phospho-FOXO1 (Thr24); 100 μg 7-26

model: 62-8388-56 brand: Sigma Aldrich Japan(Millipore)
61-0193-11 Millisnap System Flat White Adapter for Incubation On Liquid Media Cassette, 1/Pk 1ST MSLM25001
Analyzer, Testing Equipment
61-0208-22 Millex-Gv 0.22μm PVDF 33mm Gamma Sterilized 250/Pk 250PK SLGVR33RB
Analyzer, Testing Equipment