62-9147-11 [Discontinued]Earth Resistance Tester EA710DA
toner

62-9147-11 [Discontinued]Earth Resistance Tester EA710DA

model: 62-9147-11
brand: ESCO Company Ltd.
category: toner

Product Description

Product Model: 62-9147-11Product Brand: ESCO Company Lt […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 62-9147-11
Product Brand: ESCO Company Ltd.

Features

  • < Measurement frequency changeover button > Reduces the influence of harmonic ground voltage, etc., and suppresses the wobble of the guide of galvanometer.
  • * The battery included is a test battery, so please purchase a new battery.

Spec

  • Measurement System …2 Electrodes(correspond with D Type Measurement )/ 3 Electrodes(correspond with A to D Type Measurement) Alternating current Potentiometer System
  • Grounding Resistance Measurement (Measurement Range )…Microwave /Display Range /Difference permission 10 Ω /0 to 11.5 Ω /±0.25 Ω 100 Ω /0 to 115 Ω /±2.5 Ω 1000 Ω /0 to 1150 Ω /±25 Ω Measurement Frequency :575 Hz / 600 Hz Difference permission :±10 % Measurement Electric current : 3 electrodes:under 15 mA rms, 2 electrodes :under 3 mA rms Sheep Opening Circuit Voltage :under AC50 V rms
  • Ground Voltage Measurement …0 to 30 V Difference permission :±3.0 % f.s.
  • Use Temperature And Humidity Range …0 ℃ to 40 ℃, 80% rh Or Less (with no condensation)
  • Preservation Temperature And Humidity Range …-10 ℃ to 50 ℃, 80% rh Or Less (with no condensation)
  • Use Sites …Indoor ,Outdoor (exclude farm), Available under Pollution level 2 and 2000m ※It dep***s on requirements about Limitation of Opening Circuit Voltage of EN61557-5
  • Power Supply …AA Alkaline Dry Cell (LR6) x 6 Pcs (included )
  • Use Times …1100 times(LR6 At the time of ***. ) Measurement Conditions :30 Second Measurement /30 Second Stop, 3 electrodes,575 Hz, Resistance value of auxiliary earth electrode 100Ω, x 1Ω Microwave 10Ω Measurement
  • Maximam rated earth voltage …AC300 V(Measurement category Ⅱ) Expective overvoltage : 2500 V
  • Function …Measurement System Change (2 Or 3electrodes), Measurement Frequency Change (575HzOr 600Hz), Auxiliary Grounding Resistance (P/C)check
  • Overload Protection …AC250 V 1minute (E-S (P),E-H (C),between terminals)
  • Applicable cord Standard …(Safety) Body / MeasurementCircuit / Probe : EN 61010, EMC:EN61326, Earth Resistance Tester :EN61557, JIS C 1304-2002 Compliance
  • size /Weight …About 164(W) x 88(D) x 119 (H)mm/ About 800g(Only the body ,Not included Prominently like Support Foot)
  • AccessoriesAuxiliary Earth Stick (2 pcs Set ) x 1, Measurement cord (Alligator Mouth ,Black 4m) x 1, Measurement cord (Yellow 10m,Winding Device Adapted ) x 1, Measurement cord (Red 20m,Winding Device Adapted ) x 1, AA Alkaline Dry Cell x 6, Portable Case x 1

  • It becomes hard to be affected by harmonic ground voltage, etc., and it suppresses fluctuation of guidelines of galvanometer.