Features

  • By specializing in the switch function that performs on/off operation by comparing the dew point of compressed air with the set dew point, a lower price is realized.
  • Can be installed in cooling dryers and pneumatic equipment or in the piping in the immediate vicinity to **** avoid moisture damage.
  • Measured pressure dew point in the range of -30 to +30°Ctd
  • On/off 2 switch output (for limit value monitoring)
  • Capacitive humidity sensor with excellent long-term stability Test-O
  • Optional specialized software for parameter setting, adjustment, and analysis
  • Compact design for easy integration into cooling dryers and pneumatic equipment

Spec

  • Type of sensor: Capacitance type humidity sensor
  • Unit: ℃td
  • Measurement range (pressure dew-point): -30℃ to +30℃td (recomm***ed range -20 to +10℃td)
  • Measurement error: +/- 1K (> 0℃td), +/- 2K (-10 - 0℃td), +/- 3K (-20 to -10℃td), +/- 4K (-30 - 20℃td)
  • Type of temperature sensor: NTC thermistor
  • Output: Switch output 2 x potential free switch
  • Measurement frequency: 1 time/second
  • Resolution: 0.1℃ td
  • Power supply: 24V (AC/VDC), 20 - 30V (AC/VDC)
  • Power consumption: 2 wire type current/4 - 20mA, DC20/24/30 20/20/20, 4 wire type voltage/DC24/30/20 7/7/20, AC24/30 22/28
  • Outer dimensions: 167 x 33 x 33mm
  • Mass: 240g
  • Connection to the process: G1/2 inches or NPT1/2 inches
  • Protection grade: IP65 (when adapter is connected or protection cap for interface is ***d)
  • Process temperature: 0℃ to +50℃ (+10 to +35℃ ideal)
  • Storage temperature: -40 to +70℃
  • Measurement object: Compression air (filter pass/after drying, Equivalent to cleaning grade 2-4-2 of JISB8392-1)
  • Pressure resistance: Maximum 2MPa (abs)