![3-9327-01 [Discontinued]Combustion Gas Analyzer HT-2700](https://www.jgauge.com/wp-content/uploads/2025/06/525f691d67429099050e0fb19aa1ff90.webp)
toner
3-9327-01 [Discontinued]Combustion Gas Analyzer HT-2700
Product Description
Product Model: 3-9327-01Product Brand: HODAKA Co., Ltd. […]
Contact Us
Product Details
Product Model: 3-9327-01
Product Brand: HODAKA Co., Ltd.
Features
- Non-Dispersive Infrared Measurements of CO2
- Ultralight and Compact
- Color LCD Display
- Pressure and Differential Pressure Measurements
Spec
- Size (mm): 112 x 244 x 54
- Weight (g): about 880
- Target gas: oxygen
- *measuring method: Garbani battery style
- *Measurement range: 0 to 21.0 vol%
- *Accuracy: ±0.3 vol%
- *Resolution: 0.1 vol%
- *Response time: 30 seconds or less
- Target gas: carbon monoxide
- *measuring method: Constant potential electrolysis
- *Measurement range: 0 to 2000 ppm (Maximum Tolerance/10000 ppm)
- *Accuracy:. + 10 -. 10000 ppm or 0 to 2000 ppm/Measured value ppm ±5% 2001 to/Measured value ±10% (Higher value applies)
- *resolution : 1 ppm
- *Response time: 0 to 2000 ppm/within 40 seconds, 2001 to 10000 ppm/within 60 seconds
- Target gas: Nitrous oxide
- *measuring method: Constant potential electrolysis
- *Measurement range: 0 to 1000 ppm (Maximum Tolerance/3000 ppm)
- *Accuracy: ±5 ppm or 0 to 1000 ppm/Measured value ±5% 1001 to 3000 ppm/Measured value ±10% (Higher value applies)
- *resolution : 1 ppm
- *Response time: 0 to 1000 ppm/within 40 seconds, 1001 to 3000 ppm/within 60 seconds
- Target gas: Nitrous dioxide
- *measuring method: Constant potential electrolysis
- *Measurement range: 0 to 200 ppm (Maximum Tolerance/500 ppm)
- *Accuracy:. + -. 10 ppm Measurements ±10% (201 to 500 ppm)
- *resolution : 1 ppm
- *Response time: 0 to 200 ppm/within 60 seconds, 201 to 500 ppm/within 100 seconds
- Target gas: Sulfur dioxide
- *measuring method: Constant potential electrolysis
- *Measurement range: 0 to 2000 ppm (Maximum Tolerance/4000 ppm)
- *Accuracy:. + 10 -. 4000 ppm or 0 to 2000 ppm/Measured value ppm ±5% 2001 to/Measured value ±10% (Higher value applies)
- *resolution : 1 ppm
- *Response time: 0 to 2000 ppm/within 60 seconds, 2001 to 4000 ppm/within 100 seconds
- Target gas: carbon dioxide
- *measuring method: Non-distributed infrared
- *Measurement range: 0.0 to 20.0 vol%
- *Accuracy: ±0.5 vol% or ±5% of measured value (Higher value applies)
- *Resolution: 0.01 vol%
- *Response time: 1.4 to within 20.0 vol%/40 seconds, 0.0 to within 1.39 vol%/60 seconds
- Display: TFT color LCD 6/2 line switching system
- Sampling probe: Insertion length/300mm, temperature/0 to 650 ℃, hose length/2.7 m
- Power supply : AC Adapter (AC100V to 200 V 50/60Hz DC 5 V 1200 mA)
- Accessories: body, sampling probe, AC adapter, drain port, SD card (4GB), star filter, shoulder strap, pressure measuring hose, ABC Plastic case, soft case
Related product recommendations
You may also be interested in the following products
4-1600-01 [Discontinued]Small electrostatic capacity type level switch YHP-12C3
model: 4-1600-01
brand: Yamamoto Electric Industrial
63-3314-80 Timestrip: Desc***ing Temperature Indicator FCP0℃-10 FCP0-10
model: 63-3314-80
brand: Timestrip
64-7270-68 Pressure Gauge with Glycerin Pressure Range (MPa): 0.0~0.30 GV42-133-0.3MP
model: 64-7270-68
brand: NAGANO KEIKI Co., Ltd.