65-0574-39 [Discontinued]White LED and Near-Ultraviolet Light Irradiation Tester LTD-2010
laboratoryinstruments

65-0574-39 [Discontinued]White LED and Near-Ultraviolet Light Irradiation Tester LTD-2010

model: 65-0574-39
brand: TOKYO RIKAKIKAI CO., LTD.

Product Description

Product Model: 65-0574-39Product Brand: TOKYO RIKAKIKAI […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 65-0574-39
Product Brand: TOKYO RIKAKIKAI CO., LTD.

Features

  • Equipped with a white LED fluorescent lamp, the LTD-2010 can control the light, temperature and humidity of the white LED fluorescent lamp for light irradiation tests with near-ultraviolet rays. Ideal for photodegradation tests, environmental tests, irradiation and photoacceleration tests for foods, beverages, cosmetics, and photoacceleration and degradation tests for chemical products and raw materials, etc., associated with the *** of LEDs in store and facility lighting. You can also measure the exposure and intensity of near-ultraviolet rays, set and check the integrated value, and perform sample degradation and durability tests by near-ultraviolet rays.
  • You can select the control mode according to the usage status and purpose. When temperature control accuracy is required at a temperature setting above room temperature, select mode 1 (normal mode) of heater control and mode 2 (Eco mode) of energy saving operation by ON/OFF control of refrigerator.
  • The operation mode is fixed value, 2 types of program, ***r program (10 segments ×4 patterns), and automatic start/stop program operation. Various output terminals allow computer management of operating conditions, and variations are also supported.
  • White LED fluorescent lamps differ from conventional fluorescent lamps in that they have a long life, do not reduce illumination or flicker in the event of deterioration, and reduce power consumption.
  • Since the air volume adjustment function allows you to set the air volume according to the sample to be put in the cabinet, you can also *** powdery samples.
  • Displays the accumulated operating time of fluorescent lamps, humidifiers, filters, etc., so you can easily check when they are cleaned or replaced.
  • When you *** the LTD-2010, you need to submit a radio frequency equipment license application to the Ministry of Internal Affairs and Communications.

Spec

  • Convection system: Downdraft system
  • Performance:
  • Temperature control range: 5 ~ 50 degrees C (with lights off), 10 ~ 50 degrees C (with all lights on)
  • Humidity control range: 50 ~ 80% RH
  • Illumination adjustment range: 0 or 2000 ~ 24000 Lx undimmed (in 10 Lx increments)
  • Temperature and humidity control accuracy: Mode 1 (normal mode): +/- 0.5 degrees C/+/- 5% RH, Mode 2 (Eco mode): +/- 1.7 degrees C/+/- 10% RH
  • Temperature/Humidity Distribution (JTM K09): Mode 1 (Normal Mode): Spatial Temperature/Humidity Deviation, Temperature/Humidity Gradient 3.5 C/11% RH/5.5 C/17% RH, Mode 2 (Eco Mode): Spatial Temperature/Humidity Deviation, Temperature/Humidity Gradient 3.5 C/12% RH/6.0 C/18% RH
  • Illumination distribution accuracy: +/- 200 Lx/distribution +/- 10%
  • Features:
  • Temperature control: Mode 1 (normal mode): Heater control P.I.D control SSR output, Mode 2 (Eco mode): Refrigerator control ON-OFF control
  • Humidity control: P.I.D control, dehumidification control
  • Temperature/Humidity/Illumination Setting/Display: Touch panel Setting/Color Digital Display Minimum Digits: 0.1 deg. C/1% RH/10 Lx/0.01 mW/cm2/1 kLxh/0.1 mW/cm2/h, Temperature/Humidity/(cumulative) Illumination/(cumulative) Near-UV Intensity Setting, Temperature/Humidity/(cumulative) Illumination/(cumulative) Near-UV Intensity Measurement, Cumulative Time (1 to 999 days, 23 hours, 59 minutes) Batch Display/Graphic Display (Switch)
  • Defrosting function: 1. Automatic control system (during operation, 4 patterns) 2. Forced manual system (Manual Start, Automatic Stop) 3. Timer control system (Auto Start, Stop, Repeat) 4. Defrost heating and cooling
  • Other functions: RS -232 C communication terminal, recorder output terminal (Temperature, humidity, illuminance and near-ultraviolet light), alarm output terminal (contact/non-voltage type), RS -232 C connection terminal, RS -422 connection terminal, calibration of temperature and humidity display, maintenance mode, history display
  • Configuration:
  • Heater: 900 W
  • Refrigerator/Refrigerant: Air-cooled output: 400 W/R 404 A
  • Standard:
  • Humidifier: Ultrasonic humidifier (oscillator life: approximately 10,000 hours)
  • Interior Dimensions (mm), Capacity, Interior: 520 W x 520 D x 1085 H, Approx. 290 L, SUS 304
  • Shelf Board Load Capacity, Material, Number of Levels: Uniform Max. 25 kg/Sheet, PE Coating, 17 Levels
  • Number of Shelf Boards Attached/Shelf Pitch: 3/50 mm
  • Cable hole/Service outlet: 1 right side inside diameter 40 mm/Service outlet (Outside, 2 pieces, total Max. 1A)
  • Operating ambient temperature range: 5 ~ 35 degrees C
  • External Dimensions (mm)/Mass: 720 (750) W x 888 (928) D x 1810 H/Approximately 253 kg
  • Power input/voltage: 23 A, 2.3 kVA/100 VAC 50/60 Hz
  • *Performance is measured at room temperature of 20 degrees Celsius, rated supply voltage, off, 50 Hz and no load.
  • *Performance notation for temperature and humidity distributions conforms to JIS C 60068 -3 -6 JTM K 09 -2009.
  • *When humidity control is performed in Mode 1, it is operated alternately by two coolers (about every 120 minutes) and defrosted according to operating conditions. When operating with two coolers (with a large cooling capacity), there are two modes to choose from: (1) long-time operation mode (INT. MODE) with automatic defrosting by microcomputer control (approximately every 90 minutes) and short-time operation mode (CONT. mode, automatic defrosting) (2) mode 2 (defrosting by turning the refrigerator ON or OFF). Mode 2 is the on-off operation of the refrigerator, which removes frost when the refrigerator stops. If frost still occurs, set and *** timer defrost (timer forced defrost).
  • *The humidifier's overrise protection may work dep***ing on operating conditions. Mode 1 automatically switches from continuous operation of the refrigerator to ON-OFF operation of the refrigerator to reduce the load on the humidifier. In this case, the temperature and humidity adjustment accuracy is approximately +/- 1.0 degrees C/+/- 10% RH.
  • *When operating at a room temperature of 30 degrees Celsius or lower, the minimum temperature is 10 degrees Celsius when fully lit. The minimum temperature varies not only with room temperature conditions but also with the dirt on the refrigerator filter, the location of the installation, and voltage fluctuations.
  • *If humidification is controlled and the unit is operated continuously for a long period of time (1 day to 1 week or more) at a set temperature of 10 ~ 15 degrees Celsius, frost may occur in the evaporator due to changes in the surrounding environment, causing the temperature inside the unit to rise.
  • *Humidification control range and humidity control accuracy vary dep***ing on conditions (set temperature), etc.
  • *The guaranteed supply voltage is within 100 VAC +/- 5%.
  • *When humidity control is performed in Mode 1, it is operated alternately by two coolers (about every 120 minutes) and defrosted according to operating conditions. When operating with two coolers (with a large cooling capacity), there are two modes to choose from: (1) long-time operation mode (INT. MODE) with automatic defrosting by microcomputer control (approximately every 90 minutes) and short-time operation mode (CONT. mode, automatic defrosting) (2) mode 2 (defrosting by turning the refrigerator ON or OFF). Mode 2 is the on-off operation of the refrigerator, which removes frost when the refrigerator stops. If frost still occurs, set and *** timer defrost (timer forced defrost).
  • *Dimensions in parentheses include projections.
  • Power plug not included.
  • Code: 264650