68-7034-28 Portable Gas Leak Detector F (for Freon Gas) SP-230TYPEF
toner

68-7034-28 Portable Gas Leak Detector F (for Freon Gas) SP-230TYPEF

model: 68-7034-28
brand: RIKEN KEIKI Co., Ltd.
category: toner

Product Description

Product Model: 68-7034-28Product Brand: RIKEN KEIKI Co. […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 68-7034-28
Product Brand: RIKEN KEIKI Co., Ltd.

Features

  • LED display makes it easier to see! A new LED display unit is installed to notify the alarm point, gas concentration, and operating status by color and scale.
  • With full functions, it is safe to work in dark places. Equipped with an LED light that illuminates the front and a button backlight that is easy to operate with the hand.
  • You can access multiple functions with one push. Frequently ***d operations such as LED light ON/OFF, alarm/operation sound ON/OFF, alarm point switching, etc. can be operated with one push.
  • Safe design that can be ***d even in harsh environments: drop durability 2 m, protection grade equivalent to IP67, wide operating temperature range (-20~+55°C)
  • Can measure 14 kinds of CFCs in one unit. 14 CFC gases can be directly measured by switching the measuring gas.

Spec

  • Target gas: 14 kinds of CFCs (* refer to detailed catalog and operation manual)
  • Detection principle: thermal linear semiconductor type
  • Conditioning gas: R600a (isobutane)
  • Intensity display: LCD bar meter + scale +LED
  • Detection range: Measurement gas (R600a: 10~2000ppm)
  • Detection Method: Pump Suction Type
  • Alarm setting: Initial setting 30ppm (R600a: 5 levels of 10,30,150,500,2000 ppm)
  • Displays: Operating status display, flow check display, operation sound display, alarm sound display, alarm point display, battery level display, bar meter display, mode display, gas name/message display
  • Response time: 3 seconds or less
  • Gas alarm type: 1-stage alarm
  • Gas alarm display: lamp flashing/buzzer sounding
  • Gas alarm operation: automatic return
  • Failure alarm: Sensor error/Flow drop/Battery voltage drop/System error/Adjustment error/Clock error/Pump error
  • Failure alarm display: lamp blinks/buzzer sounds/failure details display
  • Failure alarm operation: self-holding
  • Power supply: AA-size alkaline batteries x 2
  • Continuous Use Time: Approx. 13 Hours (Alkaline Battery, 25°C, No Alarm, No Lighting)
  • Operating temperature range: -20 to +55°C (without sudden change)
  • Operating humidity range: 95%RH or less (no condensation)
  • Explosion-Proof Structure: Intrinsically Safe Explosion-Proof Structure
  • Explosion-Proof Class: ExiaII CT4Ga (Japan Ex)
  • Certification: CE marking, UKCA marking
  • Protection Grade: IP67 Equivalent
  • Dimensions: Approx. 186 (H) x 41 (W) x 38 (D) mm (excluding protrusions)
  • Weight: about 220 g (excluding batteries)