laboratoryinstruments
63-1396-41 Cold water circulation system ACE-1100
Product Description
Product Model: 63-1396-41Product Brand: TOKYO RIKAKIKAI […]
Contact Us
Product Details
Product Model: 63-1396-41
Product Brand: TOKYO RIKAKIKAI CO., LTD.
Features
- Cooling water circulation device for refluxing
- Cooling is performed by air cooling with a radiator. If the volume is less than 1L, cool the circulating fluid at room temperature +5°C. Suitable for refluxing solvents with a boiling point of 70°C or higher at ambient pressure.
- Since it is an air-cooled circulating device, the circulating water temperature does not fall below room temperature. In a laboratory where air conditioning is always in effect, there is no difference in the occurrence of condensation in the tube piping or in the reflux efficiency.
- The installation area is only 185 x 260 mm, which is about 1 sheet of B5 paper. The space-saving design allows you to make effective *** of draft chambers and laboratory tables.
Spec
- Sealed system counter circulation
- Cooling system: Air cooled by radiator
- Temperature setting range: Circulating water temperature from room temperature to room temperature + 5 degrees C (radiator outlet)
- Cooling capacity (at liquid temperature): Radiator heat exchange capacity 100 W
- External circulation capacity (50/60 Hz): maximum flow rate 5.0/5.8 L/min, maximum head 3.9/5.4 m
- Safety functions: Leakage/overcurrent breaker, temperature controller self-diagnosis function, forced shutdown of heating source, f*** for service outlet, circulating pump impedance protect, float water level drop detection
- Usable reaction vessel capacity: up to Max. 1 L
- Circulable Gym Funnel Tube Length: Max. 200 mm
- External circulation nozzle: One-touch connector inner diameter 10 mm, one-touch hose nozzle outer diameter 10 mm
- Service outlet: Max. 10 A for heating source
- Operating ambient temperature range: 5 ~ 35 degrees C
- External dimensions: 185 x 260 x 460 mm
- Weight: approximately 13 kg
- Power input/power supply voltage 1 A, 100 VA/AC 100 V 50/60 Hz
- *Performance is measured at room temperature of 20 degrees Celsius, rated supply voltage, 50 Hz and no load.
- *Cooling capacity and external circulation capacity are plus or minus 10% of display capacity. The cooling capacity is the value at the time of circulation of the Jimro cooling channel (200 mm tube length).
- *Power input is a value that does not include the capacity of the service outlet.
- *Pure water can not be ***d.
- Code: 253120
Related product recommendations
You may also be interested in the following products
4-2846-13 Sheet for Economy Rotator SK-R 30 L-E/SK-R 30 D-E (5 to 15 mL Tube) 18202835
model: 4-2846-13
brand: DLAB
62-2320-08 Test Sieve SUS Utility Model φ 200 mm, Depth 45 mm, Mesh Opening 5.60 mm, with Calibration Certification
model: 62-2320-08
brand: SIEVE FACTORY IIDA CO., LTD.