toner
61-9417-92 Gas Detector Tube PYROTEC Tube with Calibration Certificate (With Certificate Of Test) 51H
Product Description
Product Model: 61-9417-92Product Brand: GASTEC Corporat […]
Contact Us
Product Details
Product Model: 61-9417-92
Product Brand: GASTEC Corporation
Features
- * Please let us know the address on the certificate.
Spec
- Detecting tube name: 51H Pyrotube
- Number of measurements of 1 box: 5
- Expiration date (year): 3
- Measurement gas name: Freon11 (trichlorofluoromethane)
- Measurement range: 275 - 6600ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon112 (tetrachlorodifluoroethane)
- Measurement range: 125 - 3000ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon113 (trichlorotrifluoroethane)
- Measurement range: 250 - 6000ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: N0.840
- Measurement gas name: Freon113a (trichlorotrifluoroethane)
- Measurement range: 200 - 4800ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon114 (dichlorotetrafluoroethane)
- Measurement range: 475 - 11400ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon12 (dichlorotetrafluoroethane)
- Measurement range: 325 - 7800ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon22 (chlorodifluoromethane)
- Measurement range: 1000 - 24000ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Halothane
- Measurement range: 800 - 6400ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
Related product recommendations
You may also be interested in the following products
61-0097-07 Mini Earth Thermometer 5 0510-00
model: 61-0097-07
brand: Sato Keiryoki Mfg. Co., Ltd.
3-1575-01 [Discontinued]Platinum Resistance Thermometer Class B Three-Wire System TPT-6450
model: 3-1575-01
brand: AS ONE Corporation
61-0113-41 pH Composite Electrode (For HI98109) HI 1413S/50 HI1413S/50
model: 61-0113-41
brand: Hanna Instruments
61-0065-44 Backed Thermometer (Hook Box) -30 - 50℃ 1510-00
model: 61-0065-44
brand: Sato Keiryoki Mfg. Co., Ltd.